Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 13 von 51

Details

Autor(en) / Beteiligte
Titel
Deep learning-based synthetic CT generation for paediatric brain MR-only photon and proton radiotherapy
Ist Teil von
  • Radiotherapy and oncology, 2020-12, Vol.153, p.197-204
Ort / Verlag
Ireland: Elsevier B.V
Erscheinungsjahr
2020
Quelle
MEDLINE
Beschreibungen/Notizen
  • •A deep learning network enabled photon and proton dose calculation in a pediatric brain population.•The network generated accurate sCT even from a dataset heterogeneous in terms of demographic, anatomy, bone density and imaging protocols.•A combination of networks trained on the three orthogonal planes outperforms networks trained on single plane. To enable accurate magnetic resonance imaging (MRI)-based dose calculations, synthetic computed tomography (sCT) images need to be generated. We aim at assessing the feasibility of dose calculations from MRI acquired with a heterogeneous set of imaging protocol for paediatric patients affected by brain tumours. Sixty paediatric patients undergoing brain radiotherapy were included. MR imaging protocols varied among patients, and data heterogeneity was maintained in train/validation/test sets. Three 2D conditional generative adversarial networks (cGANs) were trained to generate sCT from T1-weighted MRI, considering the three orthogonal planes and its combination (multi-plane sCT). For each patient, median and standard deviation (σ) of the three views were calculated, obtaining a combined sCT and a proxy for uncertainty map, respectively. The sCTs were evaluated against the planning CT in terms of image similarity and accuracy for photon and proton dose calculations. A mean absolute error of 61 ± 14 HU (mean±1σ) was obtained in the intersection of the body contours between CT and sCT. The combined multi-plane sCTs performed better than sCTs from any single plane. Uncertainty maps highlighted that multi-plane sCTs differed at the body contours and air cavities. A dose difference of −0.1 ± 0.3% and 0.1 ± 0.4% was obtained on the D > 90% of the prescribed dose and mean γ2%,2mm pass-rate of 99.5 ± 0.8% and 99.2 ± 1.1% for photon and proton planning, respectively. Accurate MR-based dose calculation using a combination of three orthogonal planes for sCT generation is feasible for paediatric brain cancer patients, even when training on a heterogeneous dataset.
Sprache
Englisch
Identifikatoren
ISSN: 0167-8140
eISSN: 1879-0887
DOI: 10.1016/j.radonc.2020.09.029
Titel-ID: cdi_proquest_miscellaneous_2446672066

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX