Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 7 von 135

Details

Autor(en) / Beteiligte
Titel
Pipeline Embolization Device Versus Stent-Assisted Coiling for Intracranial Aneurysm Treatment: A Retrospective Propensity Score-Matched Study
Ist Teil von
  • Neurosurgery, 2020-09, Vol.87 (3), p.516-522
Ort / Verlag
United States: Oxford University Press
Erscheinungsjahr
2020
Quelle
Oxford Journals 2020 Medicine
Beschreibungen/Notizen
  • Abstract Background Pipeline embolization device (PED; Medtronic) and stent-assisted coiling (SAC) are established modalities for treatment of intracranial aneurysms. Objective To comparatively assess the efficacy of these techniques. Methods We conducted a retrospective analysis of patients with aneurysms treated at our institution with either PED from 2013 to 2017 or SAC from 2009 to 2015. All large (>10 mm), ruptured, fusiform, anterior communicating artery, posterior circulation aneurysms, and patients with no available follow-up imaging were eliminated before running the propensity score matching (PSM). Patients were matched using nearest neighbor controlling for: age, gender, smoking, exact location, maximal diameter, and presence of multiple aneurysms. Total hospital costs for equipment and implants were calculated from procedure product and hospital billing records, and compared between the propensity-matched pairs. Results Out of 165 patients harboring 202 aneurysms; 170 (84.2%) were treated with the PED, and 32 (15.8%) were treated using SAC. PSM resulted in 23 matched pairs; with significantly longer follow up in the SAC group (mean 29.8 vs 14.1 mo; P = .0002). Complete occlusion rates were not different (82.6 vs 87%; P = .68), with no difference between the groups for modified Rankin Scale on last clinical follow-up, procedural complications or retreatment rates. Average total costs calculated from the hospital records, including equipment and implants, were not different between propensity-score matched pairs (P = .48). Conclusion PED placement and SAC offer equally efficacious occlusion rates, functional outcomes, procedural complication rates, and cost profiles for small unruptured anterior circulation saccular aneurysms which do not involve the anterior communicating artery. Graphical Abstract Graphical Abstract

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX