Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 20 von 99
2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2019, Vol.2019, p.6413-6417
2019
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Inter-leg Distance Measurement as a Tool for Accurate Step Counting in Patients with Multiple Sclerosis
Ist Teil von
  • 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2019, Vol.2019, p.6413-6417
Ort / Verlag
United States: IEEE
Erscheinungsjahr
2019
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Step detection is commonly performed using wearable inertial devices. However, methods based on the extraction of signals features may deteriorate their accuracy when applied to very slow walkers with abnormal gait patterns. The aim of this study is to test and validate an innovative step counter method (DiSC) based on the direct measurement of inter-leg distance. Data were recorded using an innovative wearable system which integrates a magneto-inertial unit and multiple distance sensors (DSs) attached to the shank. The method allowed for the detection of both left and right steps using a single device and was validated on thirteen people affected by multiple sclerosis (0 <; EDSS <; 6.5) while performing a six-minute walking test. Two different measurement ranges for the distance sensor were tested (DS 200 : 0-200 mm; DS 400 : 0-400 mm). Accuracy was evaluated by comparing the estimates of the DiSC method against video recordings used as gold standard. Preliminary results showed a good accuracy in detecting steps with half the errors in detecting the step of the instrumented side compared to the non-instrumented (mean absolute percentage error 2.4% vs 4.8% for DS 200 ; mean absolute percentage error 2% vs 5.4% for DS 400 ). When averaging errors across patients, over and under estimation errors were compensated, and very high accuracy was achieved (E % <; 1.2% for DS 200 ; E % <; 0.7% for DS 400 ). DS 400 is the suggested configuration for patients walking with a large base of support.
Sprache
Englisch
Identifikatoren
ISSN: 1557-170X
eISSN: 1558-4615, 2694-0604
DOI: 10.1109/EMBC.2019.8857353
Titel-ID: cdi_proquest_miscellaneous_2341620028

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX