UNIVERSI
TÄ
TS-
BIBLIOTHEK
P
ADERBORN
Anmelden
Menü
Menü
Start
Hilfe
Blog
Weitere Dienste
Neuerwerbungslisten
Fachsystematik Bücher
Erwerbungsvorschlag
Bestellung aus dem Magazin
Fernleihe
Einstellungen
Sprache
Deutsch
Deutsch
Englisch
Farbschema
Hell
Dunkel
Automatisch
Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist
gegebenenfalls
nur via VPN oder Shibboleth (DFN-AAI) möglich.
mehr Informationen...
Universitätsbibliothek
Katalog
Suche
Details
Zur Ergebnisliste
Ergebnis 3 von 2986
Datensatz exportieren als...
BibTeX
Congenital Uterine Malformation by Experts (CUME): diagnostic criteria for T‐shaped uterus
Ultrasound in obstetrics & gynecology, 2020-06, Vol.55 (6), p.815-829
Ludwin, A.
Coelho Neto, M. A.
Ludwin, I.
Nastri, C. O.
Costa, W.
Acién, M.
Alcazar, J. L.
Benacerraf, B.
Condous, G.
DeCherney, A.
De Wilde, R.‐L.
Diamond, M. P.
Emanuel, M. H.
Guerriero, S.
Hurd, W.
Levine, D.
Lindheim, S.
Pellicer, A.
Petraglia, F.
Saridogan, E.
Martins, W. P.
2020
Volltextzugriff (PDF)
Details
Autor(en) / Beteiligte
Ludwin, A.
Coelho Neto, M. A.
Ludwin, I.
Nastri, C. O.
Costa, W.
Acién, M.
Alcazar, J. L.
Benacerraf, B.
Condous, G.
DeCherney, A.
De Wilde, R.‐L.
Diamond, M. P.
Emanuel, M. H.
Guerriero, S.
Hurd, W.
Levine, D.
Lindheim, S.
Pellicer, A.
Petraglia, F.
Saridogan, E.
Martins, W. P.
Titel
Congenital Uterine Malformation by Experts (CUME): diagnostic criteria for T‐shaped uterus
Ist Teil von
Ultrasound in obstetrics & gynecology, 2020-06, Vol.55 (6), p.815-829
Ort / Verlag
Chichester, UK: John Wiley & Sons, Ltd
Erscheinungsjahr
2020
Quelle
Wiley Blackwell Single Titles
Beschreibungen/Notizen
ABSTRACT Objectives To identify uterine measurements that are reliable and accurate to distinguish between T‐shaped and normal/arcuate uterus, and define T‐shaped uterus, using Congenital Uterine Malformation by Experts (CUME) methodology, which uses as reference standard the decision made most often by several independent experts. Methods This was a prospectively planned multirater reliability/agreement and diagnostic accuracy study, performed between November 2017 and December 2018, using a sample of 100 three‐dimensional (3D) datasets of different uteri with lateral uterine cavity indentations, acquired from consecutive women between 2014 and 2016. Fifteen representative experts (five clinicians, five surgeons and five sonologists), blinded to each others' opinions, examined anonymized images of the coronal plane of each uterus and provided their independent opinion as to whether it was T‐shaped or normal/arcuate; this formed the basis of the CUME reference standard, with the decision made most often (i.e. that chosen by eight or more of the 15 experts) for each uterus being considered the correct diagnosis for that uterus. Two other experienced observers, also blinded to the opinions of the other experts, then performed independently 15 sonographic measurements, using the original 3D datasets of each uterus. Agreement between the diagnoses made by the 15 experts was assessed using kappa and percent agreement. The interobserver reliability of measurements was assessed using the concordance correlation coefficient (CCC). The diagnostic test accuracy was assessed using the area under the receiver‐operating‐characteristics curve (AUC) and the best cut‐off value was assessed by calculating Youden's index, according to the CUME reference standard. Sensitivity, specificity, negative and positive likelihood ratios (LR– and LR+) and post‐test probability were calculated. Results According to the CUME reference standard, there were 20 T‐shaped and 80 normal/arcuate uteri. Individual experts recognized between 5 and 35 (median, 19) T‐shaped uteri on subjective judgment. The agreement among experts was 82% (kappa = 0.43). Three of the 15 sonographic measurements were identified as having good diagnostic test accuracy, according to the CUME reference standard: lateral indentation angle (AUC = 0.95), lateral internal indentation depth (AUC = 0.92) and T‐angle (AUC = 0.87). Of these, T‐angle had the best interobserver reproducibility (CCC = 0.87 vs 0.82 vs 0.62 for T‐angle vs lateral indentation depth vs lateral indentation angle). The best cut‐off values for these measurements were: lateral indentation angle ≤ 130° (sensitivity, 80%; specificity, 96%; LR+, 21.3; LR–, 0.21), lateral indentation depth ≥ 7 mm (sensitivity, 95%; specificity, 77.5%; LR+, 4.2; LR–, 0.06) and T‐angle ≤ 40° (sensitivity, 80%; specificity, 87.5%; LR+, 6.4; LR–, 0.23). Most of the experts diagnosed the uterus as being T‐shaped in 0% (0/56) of cases when none of these three criteria was met, in 10% (2/20) of cases when only one criterion was met, in 50% (5/10) of cases when two of the three criteria were met, and in 93% (13/14) of cases when all three criteria were met. Conclusions The diagnosis of T‐shaped uterus is not easy; the agreement among experts was only moderate and the judgement of individual experts was commonly insufficient for accurate diagnosis. The three sonographic measurements with cut‐offs that we identified (lateral internal indentation depth ≥ 7 mm, lateral indentation angle ≤ 130° and T‐angle ≤ 40°) had good diagnostic test accuracy and fair‐to‐moderate reliability and, when applied in combination, they provided high post‐test probability for T‐shaped uterus. In the absence of other anomalies, we suggest considering a uterus to be normal when none or only one criterion is met, borderline when two criteria are met, and T‐shaped when all three criteria are met. These three CUME criteria for defining T‐shaped uterus may aid in determination of its prevalence, clinical implications and best management and in the assessment of post‐surgical morphologic outcome. The CUME definition of T‐shaped uterus may help in the development of interventional randomized controlled trials and observational studies and in the diagnosis of uterine morphology in everyday practice, and could be adopted by guidelines on uterine anomalies to enrich their classification systems. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
Sprache
Englisch
Identifikatoren
ISSN: 0960-7692
eISSN: 1469-0705
DOI: 10.1002/uog.20845
Titel-ID: cdi_proquest_miscellaneous_2336987224
Format
–
Schlagworte
Accuracy
,
agreement
,
Anomalies
,
Classification systems
,
Clinical trials
,
Correlation coefficient
,
Correlation coefficients
,
Criteria
,
Datasets
,
Diagnosis
,
Diagnostic systems
,
Diagnostic tests
,
dysmorphic uterus
,
Indentation
,
Mathematical analysis
,
Medical diagnosis
,
Morphology
,
Mullerian ducts
,
Reliability analysis
,
Sensitivity
,
T‐shaped uterus
,
uterine anomalies
,
Uterus
Weiterführende Literatur
Empfehlungen zum selben Thema automatisch vorgeschlagen von
bX