Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 26 von 199

Details

Autor(en) / Beteiligte
Titel
Switching from linear to macrocyclic gadolinium‐based contrast agents halts the relative T1‐Weighted signal increase in deep gray matter of children with brain tumors: A retrospective study
Ist Teil von
  • Journal of magnetic resonance imaging, 2020-01, Vol.51 (1), p.288-295
Ort / Verlag
Hoboken, USA: John Wiley & Sons, Inc
Erscheinungsjahr
2020
Quelle
Wiley InterScience Journals
Beschreibungen/Notizen
  • Background Studies have shown signal intensity (SI) changes in the brains of children exposed to repeated doses of a gadolinium‐based contrast agent (GBCA). Hypothesis The trajectory of changes in relative dentate nucleus (DN) and globus pallidus (GP) SI in children receiving multiple doses of GBCA will alter when switched from linear to macrocyclic agents. Study Type Retrospective longitudinal. Population Thirty‐five children, age range 0.5–17.0 years, undergoing brain tumor follow‐up between 2006 and 2017. Field Strength/Sequence Unenhanced T1WI, serial scans at both 1.5T and 3T. Assessment Regions of interest were drawn on DN, GP, and SIs normalized to middle cerebellar peduncle (DN/MCP) and cerebral white matter (GP/CWM), respectively. A change in SI ratios as a function of dose (slope gradient) calculated according to the type of contrast agent received: linear only, macrocyclic only, or switchover from linear to macrocyclic. For the latter, gradients were compared before and after switchover. The effect of anticancer treatment on slope gradient was tested. Statistical Tests One‐sample t‐test or Mann–Whitney U‐test for slope gradients differing from zero. Independent samples t‐tests to compare slope gradient groups. Paired sample t‐tests to compare slope gradients before and after switchover. Results A significant (P < 0.05) increase in SI ratio was observed following multiple doses of linear but not macrocyclic agents: mean percentage increase per dose in SI was 0.063% vs. –0.034% for DN/MCP, and 0.078% vs. 0.004% for GP/CWM ratios. A significant (P < 0.05) change of SI trajectory in the DN/MCP ratio was demonstrated when switching from a linear to macrocyclic agent. There was no difference in SI trajectory between patients who had anticancer therapies and those who did not, DN/MCP P = 0.740; GP/BWM P = 0.694. Data Conclusion Switching from linear to macrocyclic gadolinium‐based contrast agents seems to halt the relative T1 signal increase in deep gray matter in children. Anticancer treatments appeared to have no impact on the trajectory of T1 SI. Level of Evidence: 4 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2020;51:288–295.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX