Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 20 von 420
Journal of magnetic resonance (1997), 2020-01, Vol.310, p.106644-106644, Article 106644
2020
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
A novel dual mode X-band EPR resonator for rapid in situ microwave heating
Ist Teil von
  • Journal of magnetic resonance (1997), 2020-01, Vol.310, p.106644-106644, Article 106644
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2020
Quelle
Elsevier ScienceDirect Journals
Beschreibungen/Notizen
  • [Display omitted] •Dual MW mode X-band CW-EPR resonator enabling in situ dielectric volumetric heating.•Easily interfaced to commercially available EPR spectrometers.•High sensitivity for organic radicals and transition metals.•T-jumps up to 5 K in a few dozen microseconds when using aqueous media. A unique dual mode X-band Continuous Wave (CW) EPR resonator designed for simultaneous EPR measurement and rapid microwave (MW) induced sample heating is described. Chemical reactions subjected to a flow of energy and matter can be perturbed away from the thermodynamic equilibrium by imposing a rapid shock or physical change to the system. Depending on the magnitude of the perturbation, these changes can dictate the subsequent evolution of the entire system, allowing for instance to populate non-equilibrium reactive intermediate states. Temperature jump (T-jump) experiments are a common method to achieve such perturbations. Most T-jump experiments are based on Joule Heating methods or IR lasers. Here we demonstrate the principle of rapid sample heating based on microwaves. The benefits of MW heating include (i) rapid and efficient heating (i.e. using a tuned resonant cavity, >99% efficient power transfer to the sample can be achieved), and (ii) volumetric heating (i.e. the entire sample volume rises in temperature at once, since heat is generated in the sample instead of being transferred to it). Accordingly, the key concept of the design is the use of a cavity resonator allowing EPR detection (at 9.5 GHz) and simultaneous sample heating (at 6.1 GHz). Temperature increments of 50 °C within a few seconds are possible. This is evidenced and illustrated here by probing the temperature-induced variation of the rotational dynamics of 16-doxyl stearic acid methyl ester (16-DSE) spin probe grafted on the surface of sodium dodecyl sulphate (SDS) micelles in water, as well as copper (II) acetylacetonate in chloroform. Rapid changes in the rotational dynamics of the paramagnetic centres provide direct evidence for the in situ and simultaneous EPR measurement-heating capabilities of the resonator. Improvements afforded by the use of pulsed MW sources will enable faster heating time scales to be achieved. In the longer term, this current study demonstrates the simple and direct possibilities for using MW heating as a means of performing T-jump experiments.
Sprache
Englisch
Identifikatoren
ISSN: 1090-7807
eISSN: 1096-0856
DOI: 10.1016/j.jmr.2019.106644
Titel-ID: cdi_proquest_miscellaneous_2322804549

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX