Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 18 von 6569

Details

Autor(en) / Beteiligte
Titel
Baseline characteristics, diagnostic efficacy, and peri-examinational safety of IV gadoteric acid MRI in 148,489 patients
Ist Teil von
  • Acta radiologica (1987), 2020-07, Vol.61 (7), p.910-920
Ort / Verlag
London, England: SAGE Publications
Erscheinungsjahr
2020
Link zum Volltext
Beschreibungen/Notizen
  • Background Magnetic resonance imaging (MRI) examinations with intravenous (IV) contrast are performed worldwide in routine daily practice. In order to detect and enumerate even rare adverse events (AE) and serious adverse events (SAE), and to relate them with patients’ baseline characteristics and diagnostic effectiveness, high quantity sample size is necessary. Purpose To assess safety, diagnostic effectiveness, and baseline characteristics of patients undergoing IV gadoteric acid (Dotarem®) MRI in routine practice. Material and Methods Data from two observational post-marketing surveillance (PMS) databases compiled by 139 and 52 German centers in 2004–2011 and 2011–2013, respectively, were pooled, yielding data on a total of 148,489 patients examined over a 10-year period. Radiologists used a standardized questionnaire to report data including patient demographics, characteristics of MR examinations, and results in terms of diagnosis and patient safety. Results Overall, 712 AEs were reported in 467 (0.3%) patients, mainly nausea (n = 224, 0.2%), vomiting (n = 29, <0.1%), urticaria (n = 20, <0.1%), and feeling hot (n = 13, <0.1%). AEs were considered related to gadoteric acid in 362 (0.2%) patients. Higher frequencies of AEs were observed among patients with a previous reaction to a contrast agent (2.0%), liver dysfunction (0.7%), bronchial asthma (0.7%), and a history of allergies (0.6%). There were 49 SAEs in 18 (<0.1%) patients, including two children. No fatal SAE was reported. Examinations were diagnostic in 99.8% of all patients, and image quality was excellent or good in 97.7% of the patients. Conclusion Gadoteric acid is a safe peri-examinational and effective contrast agent for MRI in routine practice.
Sprache
Englisch
Identifikatoren
ISSN: 0284-1851
eISSN: 1600-0455
DOI: 10.1177/0284185119883390
Titel-ID: cdi_proquest_miscellaneous_2315971096
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX