Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 7 von 58

Details

Autor(en) / Beteiligte
Titel
Efficiency, Accuracy and Clinical Applicability of a New Image-Guided Surgery System in 3D Laparoscopic Liver Surgery
Ist Teil von
  • Journal of gastrointestinal surgery, 2020-10, Vol.24 (10), p.2251-2258
Ort / Verlag
New York: Springer US
Erscheinungsjahr
2020
Link zum Volltext
Quelle
SpringerLink (Online service)
Beschreibungen/Notizen
  • Background To investigate efficiency, accuracy and clinical benefit of a new augmented reality system for 3D laparoscopic liver surgery. Methods All patients who received laparoscopic liver resection by a new image-guided surgery system with augmented 3D-imaging in a university hospital were included for analysis. Digitally processed preoperative cross-sectional imaging was merged with the laparoscopic image. Intraoperative efficiency of the procedure was measured as time needed to achieve sufficient registration accuracy. Technical accuracy was reported as fiducial registration error (FRE). Clinical benefit was assessed trough a questionnaire, reporting measures in a 5-point Likert scale format ranging from 1 (high) to 5 (low). Results From January to March 2018, ten laparoscopic liver resections of a total of 18 lesions were performed using the novel augmented reality system. Median time for registration was 8:50 min (range 1:31–23:56). The mean FRE was reduced from 14.0 mm (SD 5.0) in the first registration attempt to 9.2 mm (SD 2.8) in the last attempt. The questionnaire revealed the ease of use of the system (1.2, SD 0.4) and the benefit for resection of vanishing lesions (1.0, SD 0.0) as convincing positive aspects, whereas image registration accuracy for resection guidance was consistently judged as too inaccurate. Conclusions Augmented reality in 3D laparoscopic liver surgery with landmark-based registration technique is feasible with only little impact on the intraoperative workflow. The benefit for detecting particularly vanishing lesions is high. For an additional benefit during the resection process, registration accuracy has to be improved and non-rigid registration algorithms will be required to address intraoperative anatomical deformation.
Sprache
Englisch
Identifikatoren
ISSN: 1091-255X
eISSN: 1873-4626
DOI: 10.1007/s11605-019-04395-7
Titel-ID: cdi_proquest_miscellaneous_2306494799

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX