On-line in-tube solid phase microextraction coupled to capillary liquid chromatography-diode array detection for the analysis of caffeine and its metabolites in small amounts of biological samples
Ist Teil von
  • Journal of pharmaceutical and biomedical analysis, 2020-01, Vol.178, p.112914-112914, Article 112914
Ort / Verlag
Elsevier B.V
Erscheinungsjahr
2020
Quelle
Access via ScienceDirect (Elsevier)
Beschreibungen/Notizen
  • [Display omitted] Less than 10 μL of sample are needed for determination of caffeine and its metabolites. Low sample treatment for fast results: dilute, inject and analyze. Close correlation between serum and saliva concentrations is observed. Easy to implement in a hospital laboratory with a slight modification of a conventional HPLC system. In-tube solid phase microextraction (IT-SPME) coupled on-line to capillary liquid chromatography with diode array detection provides a simple and fast analytical methodology for the simultaneous quantitation of caffeine and its three primary metabolites (theobromine, paraxanthine and theophylline) in micro samples of serum, saliva and urine matrices. The sample amount required for one analysis was only 2.5 μL of saliva, 6.25 μL of serum or 40 μL of urine, a requirement for its implementation in a hospital laboratory for preterm newborns, where sample availability is a major problem. In standard conditions, 25 μL of diluted saliva or serum (or 100 μL of urine) were processed by IT-SPME in 30 cm of commercially available capillary GC column coated with ZB-FFAP (100% nitroterephthalic modified polyethylene glycol). The retained compounds were desorbed from the IT-SPME capillary by the mobile phase (a gradient mixture of water and methanol) and the separation was carried out in a C18 column (150 mm × 0.5 mm i.d., 5 μm particle size). Analytes eluted before 14 min, at a flow rate of 15 μL min−1, and were detected by absorbance at 275 nm. The calibration graphs presented good linearity (R2 > 0.99), without the presence of matrix effect, and recoveries between 84 and 112% were obtained. Limits of detection (S/N = 3) were 0.1 μg·mL−1 in serum and 0.5 μg·mL−1 in saliva and urine samples, for all compounds, and the intra- and inter-day variation coefficients (n = 3) were between 3 and 17%. Analytical figures of merit were similar to those proposed by other methodologies, but using lower sample volume and a faster and simpler sample treatment and analysis. Paired samples of serum and saliva from preterm newborns treated with caffeine at the pediatric intensive care unit were analyzed by the method, with statistically equivalent results for caffeine concentrations.
Sprache
Englisch
Identifikatoren
ISSN: 0731-7085
eISSN: 1873-264X
DOI: 10.1016/j.jpba.2019.112914
Titel-ID: cdi_proquest_miscellaneous_2305802037

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX