Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 14 von 741

Details

Autor(en) / Beteiligte
Titel
Impact of Prolonged Sitting on Peripheral and Central Vascular Health
Ist Teil von
  • The American journal of cardiology, 2019-01, Vol.123 (2), p.260-266
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2019
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Prolonged, uninterrupted sitting negatively impacts markers of peripheral vascular health, particularly, vasodilatory function of leg arteries. Whether sitting can similarly impact measures of central vascular health, as well as overall leg vasoreactivity (i.e., vasodilatory and vasoconstrictor function) remains unknown. To address this, measurements were made in relatively healthy participants (i.e., free of overt disease; n = 20, age = 26 ± 7; body mass index = 30 ± 7 kg/m2; 7 female) pre, during and post 3 hours of uninterrupted sitting. Measures of central vascular health included arterial wave reflection (augmentation index and Reflection Magnitude—RM%) and aortic vascular stiffness (aortic pulse wave velocity). Local vasoreactivity of the distal, posterior tibial artery was measured using flow-mediated dilation—FMD, coupled with low-flow mediated constriction, and microvascular function was assessed through the total hyperemic blood velocity (area-under-curve) response during FMD. After sitting, there was a significant increase in aortic pulse wave velocity (pre sit = 5.7 ± 0.3 vs post sit = 6.1 ± 0.3 m/s; p = 0.009, d = 0.36), whereas, augmentation index decreased (pre sit = 13 ± 3 vs post sit = 3 ± 1%; p < 0.001, d = 0.71). Albeit a moderate effect for decrease, RM% was not significantly altered during sitting (p = 0.13, d = 0.3). Vasodilatory (i.e., FMD pre sit = 0.5 ± 0.04 vs post sit = 0.3 ± 0.04 mm; p = 0.014, d = 0.29) and microvascular function (i.e., Microvascular area-under-curve: pre sit = 2,196 ± 333 vs 1,157±172 AU; p = 0.003, d = 0.31) decreased, but vasoconstrictor function (low-flow mediated constriction; p = 0.85, d = 0.005) was unaffected by sitting. In conclusion, these data demonstrate that a prolonged bout of uninterrupted sitting negatively impacts markers of peripheral and central vascular health in relatively healthy adults.
Sprache
Englisch
Identifikatoren
ISSN: 0002-9149
eISSN: 1879-1913
DOI: 10.1016/j.amjcard.2018.10.014
Titel-ID: cdi_proquest_miscellaneous_2132225114

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX