Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 6 von 44

Details

Autor(en) / Beteiligte
Titel
Autoantibodies against dsDNA measured with nonradioactive Farr assay—an alternative for routine laboratories
Ist Teil von
  • Clinical rheumatology, 2019-02, Vol.38 (2), p.353-359
Ort / Verlag
London: Springer London
Erscheinungsjahr
2019
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Autoantibodies against dsDNA are utilized for the diagnosis and prognosis of SLE as they are highly specific and correlate with disease activity/renal involvement. However, different detection methods are used in routine diagnostic laboratories. Farr radioimmunoassay (Farr-RIA) has been designated as the preferred method, since it provides very specific and at the same time quantitative results, enabling follow-up of level variations over time. Using intercalating fluorescent dsDNA dye would enable all the benefits of Farr-RIA without the radioactive material and organic solvents. To develop a modified fluorescent Farr method (Farr-FIA) and compare it to the classical Farr-RIA in regard to laboratory parameters, as well as clinical utility. Assays were tested on sera of 70 SLE patients, 78 other autoimmune patients, and 145 healthy blood donors. DNA for Farr-FIA was isolated from healthy donor, for Farr-RIA, 14 C -labeled dsDNA from E. coli was used and mixed with sera in borate-buffered saline, followed by precipitation with saturated ammonium sulfate solution and centrifugation. The supernatant (S) was separated from the precipitate (P), and content of dsDNA was measured with PicoGreen (Invitrogen) in Farr-FIA or radioactive isotope in scintillation solution in Farr-RIA. The results were calculated as a ratio (P-S)/(P+S). Farr-FIA has a diagnostic sensitivity of 53% and diagnostic specificity of 100% (ROC AUC 0.781). Good correlation and agreement were shown between Farr-RIA and Farr-FIA. Also, there is good correlation between Farr-FIA and SLEDAI, comparable to that of Farr-RIA. Farr-FIA differs from Farr-RIA in the changed detection system yielding comparable results and thus could represent a nonradioactive replacement for Farr-RIA.
Sprache
Englisch
Identifikatoren
ISSN: 0770-3198
eISSN: 1434-9949
DOI: 10.1007/s10067-018-4271-3
Titel-ID: cdi_proquest_miscellaneous_2102320651

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX