Transcatheter closure of ventricular septal defect with two different devices
Ist Teil von
Cardiology in the young, 2018-11, Vol.28 (11), p.1364-1366
Ort / Verlag
Cambridge, UK: Cambridge University Press
Erscheinungsjahr
2018
Quelle
MEDLINE
Beschreibungen/Notizen
Transcatheter closure of a multi-hole perimembranous ventricular septal defect with an aneurysm is challenging. Specific ventricular septal defect closure devices have been developed, but some occluders are reportedly used in an off-label manner. This report describes a child who had a multi-hole perimembranous ventricular septal defect with an aneurysm and underwent successful transcatheter closure using two different occluders: the Occlutech Duct Occluder (Occlutech, Helsingborg, Sweden) and the Amplatzer Duct Occluder II (St. Jude Medical, Saint Paul, Minnesota, United States of America). Transcatheter closure of a multi-hole perimembranous ventricular septal defect with an aneurysm using these two different devices can be performed safely by an experienced interventionist in selected patients.