Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Comparison of glucagon-like peptide-1 receptor (GLP-1R) PET/CT, SPECT/CT and 3T MRI for the localisation of occult insulinomas: evaluation of diagnostic accuracy in a prospective crossover imaging study
Ist Teil von
European journal of nuclear medicine and molecular imaging, 2018-12, Vol.45 (13), p.2318-2327
Ort / Verlag
Berlin/Heidelberg: Springer Berlin Heidelberg
Erscheinungsjahr
2018
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
Purpose
Benign insulinomas are the most prevalent cause of endogenous hyperinsulinaemic hypoglycaemia (EHH) in adults, and because of their small size are difficult to localise. The purpose of the study was to test the diagnostic accuracy and clinical impact of glucagon-like peptide-1 receptor (GLP-1R) PET/CT using
68
Ga-DOTA-exendin-4 in consecutive adult patients referred for localisation of insulinomas. The results were compared with
111
In-DOTA-exendin-4 SPECT/CT, study-MRI and previously performed external CT and/or MRI (prior external CT/MRI).
Methods
We prospectively enrolled patients with neuroglycopenic symptoms due to EHH. GLP-1R PET/CT, SPECT/CT and study-MRI were performed in a randomised, crossover order within 3–4 days. The reference standard was surgery with histology and treatment outcome.
Results
From January 2014 until March 2017, 52 patients were recruited. All imaging and invasive procedures before recruitment identified suspicious lesions in 46.2% of patients. GLP-1R PET/CT, SPECT/CT and study-MRI detected suspicious lesions in 78.8%, 63.5% and 63.4% of patients, respectively. In 38 patients, conclusive histology was available for final analysis.
Accuracy (95% confidence interval) for PET/CT, SPECT/CT, study-MRI and prior external CT/MRI was 93.9% (87.8–97.5%), 67.5% (58.1–76.0%), 67.6% (58.0–76.1%) and 40.0% (23.9–57.9%), respectively (all
P
values < 0.01, except comparison of SPECT/CT and study-MRI with a
P
value = 1.0). Impact on clinical management was 42.3%, 32.7% and 33.3% for PET/CT, SPECT/CT and study-MRI, respectively. Percentage reading agreement was 89.5%, 75.7%, and 71.1% for PET/CT, SPECT/CT and study-MRI, respectively.
Conclusion
68
Ga-DOTA-exendin-4 PET/CT performed significantly better than
111
In-DOTA-exendin-4 SPECT/CT and MRI in the localisation of benign insulinomas and should be considered in patients where localisation fails with CT/MRI (
ClinicalTrials.gov
, NCT02127541).