Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 23 von 42

Details

Autor(en) / Beteiligte
Titel
Periprosthetic acetabular radiolucency progression in mid-term follow-up of the articular surface replacement hip system
Ist Teil von
  • Archives of orthopaedic and trauma surgery, 2018-07, Vol.138 (7), p.1021-1028
Ort / Verlag
Berlin/Heidelberg: Springer Berlin Heidelberg
Erscheinungsjahr
2018
Quelle
SpringerLink Journals - AutoHoldings
Beschreibungen/Notizen
  • Introduction Recent registry studies show that aseptic loosening secondary to osteolysis is the second leading cause of hip implant failure in patients implanted with metal-on-metal (MoM) bearings. The primary aim of our study was to report on the progression of acetabular osteolysis during mid-term follow-up in patients treated with MoM hip resurfacing arthroplasty (HRA) and MoM total hip arthroplasty (THA). The secondary aim was to identify independent predictors of osteolytic lesion progression. Materials and methods A total of 805 patients (805 hips) were included in this study (541 MoM HRA, 264 MoM THA) from a prospective, international clinical registry of the Articular Surface Replacement Hip System. Patients were enrolled a median of 6.6 years from surgery. Osteolytic lesion progression was defined either as any lesion developing de novo, or as an existing lesion progressing from radiolucency to osteolysis during the study period (range 0.5–4.3 years). Results The number of cases with any osteolysis or radiolucency was 21 (3.9%) for ASR HRA and 29 (11.0%) for ASR XL THA at enrollment and increased to 69 (12.8%) for ASR HRA and 41 (15.5%) for ASR XL THA after follow-up. Osteolytic lesion progression was found in 66 (12.2%) ASR HRA patients and 31 (11.7%) ASR XL THA patients. Multivariate models determined that lower acetabular version angle (OR 0.963, p  = 0.011) and elevated whole blood chromium (OR 1.110, p  = 0.044) were independent predictors of osteolytic lesion progression in ASR HRA. Conclusion We suggest that physicians of patients implanted with ASR HRA implants closely monitor patients with higher chromium levels and lower version angles, as they are at increased risk for osteolytic lesion progression, and we recommend annual radiographic follow-up on all patients with ASR implants.
Sprache
Englisch
Identifikatoren
ISSN: 0936-8051
eISSN: 1434-3916
DOI: 10.1007/s00402-018-2962-5
Titel-ID: cdi_proquest_miscellaneous_2050486222

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX