Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 6 von 3187

Details

Autor(en) / Beteiligte
Titel
Body fluid identification using a targeted mRNA massively parallel sequencing approach – results of a EUROFORGEN/EDNAP collaborative exercise
Ist Teil von
  • Forensic science international : genetics, 2018-05, Vol.34, p.105-115
Ort / Verlag
Netherlands: Elsevier B.V
Erscheinungsjahr
2018
Quelle
Access via ScienceDirect (Elsevier)
Beschreibungen/Notizen
  • •Targeted RNA sequencing assay for body fluid identification tested within 17 EUROFORGEN/EDNAP laboratories.•Identification of stains containing blood, semen, saliva, vaginal secretion, menstrual blood and skin.•2 assays containing 33 and 29 biomarkers for Illumina MiSeq/FGx and Ion Torrent PGM/S5, respectively.•Statistical analysis of results using partial least squares analysis (PLS). In a previous study we presented an assay for targeted mRNA sequencing for the identification of human body fluids, optimised for the Illumina MiSeq/FGx MPS platform. This assay, together with an additional in-house designed assay for the Ion Torrent PGM/S5 platform, was the basis for a collaborative exercise within 17 EUROFORGEN and EDNAP laboratories, in order to test the efficacy of targeted mRNA sequencing to identify body fluids. The task was to analyse the supplied dried body fluid stains and, optionally, participants’ own bona fide or mock casework samples of human origin, according to specified protocols. The provided primer pools for the Illumina MiSeq/FGx and the Ion Torrent PGM/S5 platforms included 33 and 29 body fluid specific targets, respectively, to identify blood, saliva, semen, vaginal secretion, menstrual blood and skin. The results demonstrated moderate to high count values in the body fluid or tissue of interest with little to no counts in non-target body fluids. There was some inter-laboratory variability in read counts, but overall the results of the laboratories were comparable in that highly expressed markers showed high read counts and less expressed markers showed lower counts. We performed a partial least squares (PLS) analysis on the data, where blood, menstrual blood, saliva and semen markers and samples clustered well. The results of this collaborative mRNA massively parallel sequencing (MPS) exercise support targeted mRNA sequencing as a reliable body fluid identification method that could be added to the repertoire of forensic MPS panels.
Sprache
Englisch
Identifikatoren
ISSN: 1872-4973
eISSN: 1878-0326
DOI: 10.1016/j.fsigen.2018.01.002
Titel-ID: cdi_proquest_miscellaneous_2003045134

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX