Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 11 von 301

Details

Autor(en) / Beteiligte
Titel
Homochiral porous organic cage used as stationary phase for open tubular capillary electrochromatography
Ist Teil von
  • Analytica chimica acta, 2018-01, Vol.999, p.169-175
Ort / Verlag
Netherlands: Elsevier B.V
Erscheinungsjahr
2018
Quelle
Access via ScienceDirect (Elsevier)
Beschreibungen/Notizen
  • Porous organic molecular cages, as a new type of porous materials, have in recent years attracted a tremendous amount of attention for their potential applications. However, to the best of our knowledge, there has been no attempt to utilize porous organic molecular cages as stationary phases in capillary electrochromatography (CEC). We report herein the use of a homochiral porous organic cage (POC) (CC3-R) as a stationary phase in open tubular capillary electrochromatography (OT-CEC) for the separation of chiral compounds and positional isomers. The column was fabricated using CC3-R as the stationary phase by a static coating method. Separation of furoin, benzoin, and alprenlol were achieved on the CC3-R coated column, with the highest resolution value (Rs = 3.35) for the separation of benzoin. The influences of pH and buffer concentration on separation have been investigated. Besides, the CC3-R column also exhibited good selectivity for the separation of positional isomers, including those of nitrophenols, phenylenediamines, aminophenols, and ionones. The run-to-run (n = 5), day-to-day (n = 5), column-to-column (n = 3), and batch-to-batch (n = 3) relative standard deviations (RSDs) for the analyte migration time were in the range of 0.5–1.5%, 0.2–1.8%, 1.2–2.1% and 1.5–2.8%, respectively. The RSDs for the migration time and enantioselectivity of the analyte were less than 5.9% and 2.2% (inter-day, n = 5) after a week of continuous use. This work also indicates that porous organic molecular materials are promising for enantioseparation in CEC and look set to become more attractive in separation science. [Display omitted] •A novel porous organic cage (POC) coated chiral OT capillary column was developed.•This is a report, for the first time, that the enantioseparations are carried out by POC (CC3-R) in CEC.•Good enantioseparation for furoin, benzoin and alprenlol were achieved.•The isomers of nitrophenols, phenylenediamines, aminophenols and ionones were also separated.
Sprache
Englisch
Identifikatoren
ISSN: 0003-2670
eISSN: 1873-4324
DOI: 10.1016/j.aca.2017.11.021
Titel-ID: cdi_proquest_miscellaneous_1978719135

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX