Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 14 von 802

Details

Autor(en) / Beteiligte
Titel
Clinical Results and Technical Complications of Posterior Implant‐Supported Modified Monolithic Zirconia Single Crowns and Short‐Span Fixed Dental Prostheses: A 2‐Year Pilot Study
Ist Teil von
  • Journal of prosthodontics, 2018-02, Vol.27 (2), p.108-114
Ort / Verlag
United States: Wiley Subscription Services, Inc
Erscheinungsjahr
2018
Quelle
Wiley Online Library Journals Frontfile Complete
Beschreibungen/Notizen
  • Purpose The purpose of this clinical trial was to investigate the clinical outcomes of implant‐supported modified monolithic zirconia single crowns (SCs) and short‐span fixed dental prostheses (FDPs) after a follow‐up of 2 years. Materials and Methods Twenty‐seven patients in need of implant‐supported SCs or 3‐unit FDPs in the posterior maxilla or mandible were consecutively selected for this study. A total of 56 modified monolithic zirconia prostheses including 44 SCs (8 screw‐retained, 36 cement‐retained) and twelve 3‐unit FDPs (5 screw‐retained, 7 cement‐retained) were included in this study. All patients were followed at 6 months, 12 months, 18 months, and 2 years after placement of the modified monolithic zirconia prostheses. During the follow‐up period, all prostheses were evaluated with clinical and radiographic examinations. The following technical parameters were assessed: framework fracture, fracture of veneering porcelain, screw loosening, loss of retention because of prosthesis de‐cementation and opposing tooth fracture. Results No implant was lost during the follow‐up period, yielding a 2‐year implant survival of 100%. One FDP failed because of framework fracture. The overall prosthesis survival rate was 98.2% after 2 years of clinical service. During the study, 5 complication events were observed in 3 SCs and one FDP, including one fracture of veneering porcelain and 2 screw loosenings in 3 SCs, and loss of retention and opposing tooth fracture in the same FDP. Therefore, the complication‐free rate of prostheses was 91.1%. Conclusion According to the results of this study, the modified monolithic zirconia design used in this study resulted in a favorable short‐term outcome for posterior implant‐supported SCs and 3‐unit FDPs.
Sprache
Englisch
Identifikatoren
ISSN: 1059-941X
eISSN: 1532-849X
DOI: 10.1111/jopr.12682
Titel-ID: cdi_proquest_miscellaneous_1958536112

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX