Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 26 von 31

Details

Autor(en) / Beteiligte
Titel
Utility of nociceptive flexion reflex threshold and bispectral index to predict movement responses under propofol anaesthesia
Ist Teil von
  • Somatosensory & motor research, 2017-04, Vol.34 (2), p.139-144
Ort / Verlag
England: Taylor & Francis
Erscheinungsjahr
2017
Quelle
MEDLINE
Beschreibungen/Notizen
  • Introduction: The nociceptive flexion reflex threshold (NFRT) is a promising tool to monitor analgesia during general anaesthesia. Clinical studies have shown that the NFRT allows to predict movement responses to painful stimuli under a combined anaesthetic regime of sedative and opioid agents. Experimental studies indicated that the NFRT is also able to predict such movement responses under an exclusively sedative regime like propofol mono-anaesthesia. Therefore, we performed this study to investigate the ability of the NFRT to predict movement responses to painful stimuli in patients during a clinical propofol mono-anaesthesia. Methods: We investigated 140 cardiac surgery patients during their postoperative phase under propofol mono-anaesthesia. NFRT and bispectral index (BIS) were determined in each patient right before endotracheal suctioning or painful electrical test stimulation. Prediction probabilities were calculated to quantify how accurate each measure is able to predict movement responses to the stimuli. Results: The 124 patients included in the analysis received a median propofol dosage of 3.2 (2.5-3.9) [median (IQR)] mg/kg/h. The included patients showed 287 movement responses after a total of 725 investigated stimuli. The prediction probabilities for positive movement responses were 0.63 (95%CI: 0.59-0.67) for the NFRT and 0.69 (95%CI: 0.65-0.73) for the BIS. Conclusions: The NFRT allows the prediction of movement responses under propofol mono-anaesthesia, which confirms its utility as a monitor to predict movement responses under general anaesthesia. The BIS allows an even more accurate prediction, although it does not reflect the physiological structures of movement suppression, but correlates closely with the dose of propofol. Trial registration: German clinical trial register (DRKS00003062, Deutsches Register Klinischer Studien).
Sprache
Englisch
Identifikatoren
ISSN: 0899-0220
eISSN: 1369-1651
DOI: 10.1080/08990220.2017.1343189
Titel-ID: cdi_proquest_miscellaneous_1916382376

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX