Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 8 von 306

Details

Autor(en) / Beteiligte
Titel
Development of the open‐source dose calculation and optimization toolkit matRad
Ist Teil von
  • Medical physics (Lancaster), 2017-06, Vol.44 (6), p.2556-2568
Ort / Verlag
United States
Erscheinungsjahr
2017
Quelle
Wiley Online Library - AutoHoldings Journals
Beschreibungen/Notizen
  • Purpose We report on the development of the open‐source cross‐platform radiation treatment planning toolkit matRad and its comparison against validated treatment planning systems. The toolkit enables three‐dimensional intensity‐modulated radiation therapy treatment planning for photons, scanned protons and scanned carbon ions. Methods matRad is entirely written in Matlab and is freely available online. It re‐implements well‐established algorithms employing a modular and sequential software design to model the entire treatment planning workflow. It comprises core functionalities to import DICOM data, to calculate and optimize dose as well as a graphical user interface for visualization. matRad dose calculation algorithms (for carbon ions this also includes the computation of the relative biological effect) are compared against dose calculation results originating from clinically approved treatment planning systems. Results We observe three‐dimensional γ‐analysis pass rates ≥ 99.67% for all three radiation modalities utilizing a distance to agreement of 2 mm and a dose difference criterion of 2%. The computational efficiency of matRad is evaluated in a treatment planning study considering three different treatment scenarios for every radiation modality. For photons, we measure total run times of 145 s–1260 s for dose calculation and fluence optimization combined considering 4–72 beam orientations and 2608–13597 beamlets. For charged particles, we measure total run times of 63 s–993 s for dose calculation and fluence optimization combined considering 9963–45574 pencil beams. Using a CT and dose grid resolution of 0.3 cm3 requires a memory consumption of 1.59 GB–9.07 GB and 0.29 GB–17.94 GB for photons and charged particles, respectively. Conclusion The dosimetric accuracy, computational performance and open‐source character of matRad encourages a future application of matRad for both educational and research purposes.
Sprache
Englisch
Identifikatoren
ISSN: 0094-2405
eISSN: 2473-4209
DOI: 10.1002/mp.12251
Titel-ID: cdi_proquest_miscellaneous_1884167720

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX