Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 15 von 268

Details

Autor(en) / Beteiligte
Titel
GEANT4 models for the secondary radiation flux in the collimation system of a 300MeV proton microbeam
Ist Teil von
  • Physica medica, 2016-12, Vol.32 (12), p.1841-1845
Ort / Verlag
Italy: Elsevier Ltd
Erscheinungsjahr
2016
Quelle
Access via ScienceDirect (Elsevier)
Beschreibungen/Notizen
  • •A bending collimation system to reduce the collimator scattering in a 300MeV proton microbeam is proposed.•The influences of collimator material and proton energy in the bending collimation system are systematically invested.•The limitation of vacuum pressure is invested for a 300MeV proton microbeam. In Harbin, we are developing a 300MeV proton microbeam for many applications in space science including upset studies in microelectronic devices, radiation hardness of materials for satellites and radiation effects in human tissues. There are also applications of this facility proposed for proton therapy. The microbeam system will employ a purpose-built proton synchrotron to provide the beam. However there are many challenges to be addressed in the design, construction and operation of this facility. Here we address two important design aspects for which we apply GEANT4 modeling. First, the high energy proton beam interacts strongly with beam line materials, especially the collimation slits, to produce showers of secondary particles which could introduce significant background signals and degrade the resolution of the proton microbeam. Second, the beam transport within the residual vacuum of the beam line may also introduce undesirable background radiation. In both cases mitigation strategies need to be incorporated during the design phase of the new system. We study the use of a dipole magnet following the aperture collimator to reduce the flux of secondary particles incident on the analysis chamber. Monte Carlo simulations are performed using GEANT4 and SRIM. By inserting the dipole magnet, we find as expected a significant reduction in the scattering of protons and other particles, such as neutrons and gamma rays, at the collimation system exit position. Secondary radiation from the residual gas pressure within the beam line vacuum system are also modelled and found to be negligible under the standard operating conditions.
Sprache
Englisch
Identifikatoren
ISSN: 1120-1797
eISSN: 1724-191X
DOI: 10.1016/j.ejmp.2016.10.008
Titel-ID: cdi_proquest_miscellaneous_1881266385

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX