Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 15 von 253
EURASIP journal on advances in signal processing, 2012-07, Vol.2012 (1), p.1-11, Article 143
2012
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Instantaneous frequency based newborn EEG seizure characterisation
Ist Teil von
  • EURASIP journal on advances in signal processing, 2012-07, Vol.2012 (1), p.1-11, Article 143
Ort / Verlag
Cham: Springer International Publishing
Erscheinungsjahr
2012
Quelle
SpringerLink
Beschreibungen/Notizen
  • The electroencephalogram (EEG), used to noninvasively monitor brain activity, remains the most reliable tool in the diagnosis of neonatal seizures. Due to their nonstationary and multi-component nature, newborn EEG seizures are better represented in the joint time-frequency domain than in either the time domain or the frequency domain. Characterising newborn EEG seizure nonstationarities helps to better understand their time-varying nature and, therefore, allow developing efficient signal processing methods for both modelling and seizure detection and classification. In this article, we used the instantaneous frequency (IF) extracted from a time-frequency distribution to characterise newborn EEG seizures. We fitted four frequency modulated (FM) models to the extracted IFs, namely a linear FM, a piecewise-linear FM, a sinusoidal FM, and a hyperbolic FM. Using a database of 30-s EEG seizure epochs acquired from 35 newborns, we were able to show that, depending on EEG channel, the sinusoidal and piecewise-linear FM models best fitted 80-98% of seizure epochs. To further characterise the EEG seizures, we calculated the mean frequency and frequency span of the extracted IFs. We showed that in the majority of the cases (>95%), the mean frequency resides in the 0.6-3 Hz band with a frequency span of 0.2-1 Hz. In terms of the frequency of occurrence of the four seizure models, the statistical analysis showed that there is no significant difference( p = 0.332) between the two hemispheres. The results also indicate that there is no significant differences between the two hemispheres in terms of the mean frequency ( p = 0.186) and the frequency span ( p = 0.302).
Sprache
Englisch
Identifikatoren
ISSN: 1687-6180
eISSN: 1687-6180
DOI: 10.1186/1687-6180-2012-143
Titel-ID: cdi_proquest_miscellaneous_1864539644

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX