Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 24 von 895

Details

Autor(en) / Beteiligte
Titel
Diagnostic accuracy of fractional exhaled nitric oxide measurement in predicting cough-variant asthma and eosinophilic bronchitis in adults with chronic cough: A systematic review and meta-analysis
Ist Teil von
  • Journal of allergy and clinical immunology, 2017-09, Vol.140 (3), p.701-709
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2017
Quelle
MEDLINE
Beschreibungen/Notizen
  • Background Individual studies have suggested the utility of fractional exhaled nitric oxide (F eno ) measurement in detecting cough-variant asthma (CVA) and eosinophilic bronchitis (EB) in patients with chronic cough. Objective We sought to obtain summary estimates of diagnostic test accuracy of F eno measurement in predicting CVA, EB, or both in adults with chronic cough. Methods Electronic databases were searched for studies published until January 2016, without language restriction. Cross-sectional studies that reported the diagnostic accuracy of F eno measurement for detecting CVA or EB were included. Risk of bias was assessed with Quality Assessment of Diagnostic Accuracy Studies 2. Random effects meta-analyses were performed to obtain summary estimates of the diagnostic accuracy of F eno measurement. Results A total of 15 studies involving 2187 adults with chronic cough were identified. F eno measurement had a moderate diagnostic accuracy in predicting CVA in patients with chronic cough, showing the summary area under the curve to be 0.87 (95% CI, 0.83-0.89). Specificity was higher and more consistent than sensitivity (0.85 [95% CI, 0.81-0.88] and 0.72 [95% CI, 0.61-0.81], respectively). However, in the nonasthmatic population with chronic cough, the diagnostic accuracy to predict EB was found to be relatively lower (summary area under the curve, 0.81 [95% CI, 0.77-0.84]), and specificity was inconsistent. Conclusions The present meta-analyses indicated the diagnostic potential of F eno measurement as a rule-in test for detecting CVA in adult patients with chronic cough. However, F eno measurement may not be useful to predict EB in nonasthmatic subjects with chronic cough. These findings warrant further studies to validate the roles of F eno measurement in clinical practice of patients with chronic cough.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX