Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 20 von 104

Details

Autor(en) / Beteiligte
Titel
Advanced diffusion models in head and neck squamous cell carcinoma patients: Goodness of fit, relationships among diffusion parameters and comparison with dynamic contrast-enhanced perfusion
Ist Teil von
  • Magnetic resonance imaging, 2017-02, Vol.36, p.16-23
Ort / Verlag
Netherlands: Elsevier Inc
Erscheinungsjahr
2017
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • We assessed advanced fitting models of diffusion weighted imaging (DWI) in head/neck squamous cell carcinoma (HNSCC) patients to determine the best goodness of fit and correlations among diffusion parameters. We compared these results with those of dynamic contrast-enhanced (DCE) perfusion parameters. We retrospectively evaluated 32 HNSCC patients (12 sinonasal, 20 pharynx/oral cavity). The DWI acquisition used single-shot spin-echo echo-planar imaging (EPI) with 12 b-values (0−2000). We calculated 14 DWI parameters using mono-exponential, bi-exponential, and tri-exponential models, stretched exponential model (SEM) and diffusion kurtosis imaging (DKI) models. We compared each model's goodness of fit using the residual sum of squares (RSS), Akaike Information Criterion (AIC) and Bayesian information criterion (BIC) value. We determined the correlation between each pair of DWI parameters and between each DWI parameter and DCE perfusion parameter. The tri-exponential fit's RSS, AIC and BIC values were significantly smaller than those for bi-exponential fit. The RSS, AIC and BIC values of the SEM fit and DKI fit were significantly smaller than mono-exponential model. Significant correlations were observed in 30 pairs (sinonasal cavity) and 31 (sinonasal cavity group) among 91 DWI parameter combinations. Significant correlations were also observed in nine pairs (both sinonasal cavity and pharynx/oral cavity group) among 64 DWI/DCE perfusion parameter pairs, in particular, high positive correlations between the tri-exponential model's intermediate diffusion fraction (f2) and the volume of the extracellular extravascular space per unit volume of tissue (ve) were observed in both patient groups. We identified several correlations between DWI parameters by advanced fitting models and correlations between DWI and DCE parameters. These will help determine HNSCC patients' detailed tissue structures.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX