Intra- and Inter-rater Reliability of Coronal Curvature Measurement for Adolescent Idiopathic Scoliosis Using Ultrasonic Imaging Method—A Pilot Study
Ist Teil von
  • Spine deformity, 2015-03, Vol.3 (2), p.151-158
Ort / Verlag
Cham: Elsevier Inc
Erscheinungsjahr
2015
Quelle
SpringerLink
Beschreibungen/Notizen
  • Abstract Study Design Retrospective reliability study of the coronal curvature measurement on ultrasound (US) imaging in adolescent idiopathic scoliosis (AIS). Objectives To determine the intra- and inter-rater reliability and validity of the coronal curvature measurements obtained from US images. Summary of Background Data Cobb angle measurements on radiographs are the usual method to diagnose and monitor the progression of scoliosis. Repeated ionizing radiation exposure is a frequent concern of patients and their families. Use of US imaging method to measure coronal curvature in children who have idiopathic scoliosis has not been clinically validated. Methods The researchers scanned 26 subjects using a medical 3-dimensional US system. Spinal radiographs were obtained on the same day from the local scoliosis clinic. Three raters used the center of lamina method to measure the coronal curvature on the US images twice 1 week apart. The raters also measured the Cobb angle on the radiographs twice. Intra- and inter-rater reliability of the coronal curvature measurement from the US images was analyzed using intra-class correlation coefficients. The correlation coefficient of the US coronal curvature measurements was compared with the Cobb angles. Results The intra-class correlation coefficient (2,1) values of intra- and inter-rater reliability on the US method were greater than 0.80. Standard error of measurement on both of the intra- and inter-rater US methods was less than 2.8°. The correlation coefficient between the US and radiographic methods ranged between 0.78 and 0.84 among 3 raters. Conclusions The US method illustrated substantial intra- and inter-rater reliability. The measurement difference between radiography and the US method was within the range of clinically acceptable error (5°). The US method may be considered a radiation-free alternative to assess children with scoliosis of mild to moderate severity.
Sprache
Englisch
Identifikatoren
ISSN: 2212-134X
eISSN: 2212-1358
DOI: 10.1016/j.jspd.2014.08.008
Titel-ID: cdi_proquest_miscellaneous_1847881881

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX