Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 26 von 6590

Details

Autor(en) / Beteiligte
Titel
Assessment of air quality microsensors versus reference methods: The EuNetAir joint exercise
Ist Teil von
  • Atmospheric environment (1994), 2016-12, Vol.147, p.246-263
Ort / Verlag
Elsevier Ltd
Erscheinungsjahr
2016
Quelle
Elsevier ScienceDirect Journals
Beschreibungen/Notizen
  • The 1st EuNetAir Air Quality Joint Intercomparison Exercise organized in Aveiro (Portugal) from 13th–27th October 2014, focused on the evaluation and assessment of environmental gas, particulate matter (PM) and meteorological microsensors, versus standard air quality reference methods through an experimental urban air quality monitoring campaign. The IDAD-Institute of Environment and Development Air Quality Mobile Laboratory was placed at an urban traffic location in the city centre of Aveiro to conduct continuous measurements with standard equipment and reference analysers for CO, NOx, O3, SO2, PM10, PM2.5, temperature, humidity, wind speed and direction, solar radiation and precipitation. The comparison of the sensor data generated by different microsensor-systems installed side-by-side with reference analysers, contributes to the assessment of the performance and the accuracy of microsensor-systems in a real-world context, and supports their calibration and further development. The overall performance of the sensors in terms of their statistical metrics and measurement profile indicates significant differences in the results depending on the platform and on the sensors considered. In terms of pollutants, some promising results were observed for O3 (r2: 0.12–0.77), CO (r2: 0.53–0.87), and NO2 (r2: 0.02–0.89). For PM (r2: 0.07–0.36) and SO2 (r2: 0.09–0.20) the results show a poor performance with low correlation coefficients between the reference and microsensor measurements. These field observations under specific environmental conditions suggest that the relevant microsensor platforms, if supported by the proper post processing and data modelling tools, have enormous potential for new strategies in air quality control. •Several air quality microsensors were tested against reference methods.•Significant differences in the results depending on the platform and on the sensors.•Promising results were observed for O3, CO and NO2 sensors.•The sensors can improve spatiotemporal resolution of data to complement existing air quality monitoring networks.
Sprache
Englisch
Identifikatoren
ISSN: 1352-2310
eISSN: 1873-2844
DOI: 10.1016/j.atmosenv.2016.09.050
Titel-ID: cdi_proquest_miscellaneous_1846421771

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX