Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 9 von 114

Details

Autor(en) / Beteiligte
Titel
Zotarolimus-Eluting Versus Bare-Metal Stents in Uncertain Drug-Eluting Stent Candidates
Ist Teil von
  • Journal of the American College of Cardiology, 2015-03, Vol.65 (8), p.805-815
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2015
Quelle
MEDLINE
Beschreibungen/Notizen
  • Abstract Background The use of drug-eluting stents (DES) in patients at high risk of bleeding or thrombosis has not been prospectively studied; limited data are available in patients who have a low restenosis risk. Objectives This study sought to compare a hydrophilic polymer-based, second-generation zotarolimus-eluting stent (ZES) with a unique drug fast-release profile versus bare-metal stents (BMS) under similar durations of dual-antiplatelet therapy (DAPT). Methods We randomly assigned 1,606 patients with stable or unstable symptoms, and who on the basis of thrombotic bleeding or restenosis risk criteria, qualified as uncertain candidates for DES, to receive ZES or BMS. DAPT duration was on the basis of patient characteristics, rather than stent characteristics, and allowed for a personalized 1-month dual antiplatelet regimen. The primary endpoint was the risk of 1-year major adverse cardiovascular events (MACE), which included death, myocardial infarction (MI), or target vessel revascularization (TVR). Results Median DAPT duration was 32 days (interquartile range [IQR]: 30 to 180 days) and did not differ between the groups. In the ZES group, 140 patients (17.5%) reached the primary endpoint, compared with 178 patients (22.1%) in the BMS group (hazard ratio: 0.76; 95% confidence interval: 0.61 to 0.95; p = 0.011) as a result of lower MI (2.9% vs. 8.1%; p < 0.001) and TVR rates (5.9% vs.10.7%; p = 0.001) in the ZES group. Definite or probable stent thrombosis was also significantly reduced in ZES recipients (2.0% vs. 4.1%; p = 0.019). Conclusions Compared with BMS, DES implantation using a stent with a biocompatible polymer and fast drug-eluting characteristics, combined with an abbreviated, tailored DAPT regimen, resulted in a lower risk of 1-year MACE in uncertain candidates for DES implantation. (Zotarolimus-eluting Endeavor Sprint Stent in Uncertain DES Candidates [ZEUS] Study; NCT01385319 )

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX