Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 22 von 432
Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms, 2016-06, Vol.377, p.67-76
2016

Details

Autor(en) / Beteiligte
Titel
Thermoluminescence characteristics of Israeli household salts for retrospective dosimetry in radiological events
Ist Teil von
  • Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms, 2016-06, Vol.377, p.67-76
Ort / Verlag
Elsevier B.V
Erscheinungsjahr
2016
Link zum Volltext
Quelle
Elsevier ScienceDirect Journals Complete
Beschreibungen/Notizen
  • •Examination the potential use of Israeli household salt as a retrospective dosimeter.•Detailed investigation of the basic dosimetric characteristics of the salts.•It is shown that computerized glow curve analysis for accurate background subtraction and dose measurement is required. Following a nuclear accident or terror attack involving the dispersal of radioactive substances, radiation dose assessment to first responders and the members of the public is essential. The need for a retrospective assessment of the radiation dose to those possibly affected is, therefore, obligatory. The present study examines the potential use of Israeli household salt as a retrospective dosimeter (RD). The experiments were carried out on Israeli salt samples (NaCl) following a Nielsen market track survey based on scanning data representing the barcoded market, including organized and independent retail chains and a sample of private minimarkets and supermarkets. The technique used was thermoluminescence (TL) dosimetry. Salt samples were exposed to levels of dose from 0.5mGy to 300Gy at the Israeli Secondary Standard Dosimetry Laboratory of the Soreq Nuclear Research Center using a calibrated 137Cs source. Our emphasis has been on a detailed investigation of the basic dosimetric characteristics of the salts including: (i) glow curve analysis (ii) individual glow peak dose response (iii) reproducibility (iv) estimation of minimal measurable dose (v) effect of nitrogen readout, (vi) influence of humidity during pre-irradiation storage and (vii) light induced fading. The results are sufficiently favorable to lead to the conclusion that the Israeli household salts can serve as a pragmatic potential candidate for RD under certain restricted conditions. Occasional pre-calibration of the major salt brands in a dedicated laboratory may be essential depending on the required accuracy in the estimation of dose and consequent clinical evaluation.
Sprache
Englisch
Identifikatoren
ISSN: 0168-583X
eISSN: 1872-9584
DOI: 10.1016/j.nimb.2016.04.024
Titel-ID: cdi_proquest_miscellaneous_1816009523

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX