Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Reliability of the Determination of the Ventilatory Threshold in Patients with COPD
Ist Teil von
Medicine and science in sports and exercise, 2016-02, Vol.48 (2), p.210-218
Ort / Verlag
United States: American College of Sports Medicine
Erscheinungsjahr
2016
Quelle
MEDLINE
Beschreibungen/Notizen
PURPOSEThe purpose of this study was to determine the interobserver reliability of the assessment of the ventilatory threshold (VT) using two methods in patients with chronic obstructive pulmonary disease (COPD) and in control subjects.
METHODSVT was identified from incremental exercise testing graphs of 115 subjects (23 controls and 23 in each COPD Global initiative for chronic Obstructive Lung Disease class) by two human observers and a computer analysis using the V-slope method and the ventilatory equivalent method (VEM). Agreement between observers in identifying oxygen uptake at VT (V˙O2VT) and HR at VT (HRVT) across disease severity groups was evaluated using intraclass correlation (for humans) and Passing–Bablok regression analysis (human vs computer).
RESULTSFor human observers, ICC (95% confidence interval) in determining V˙O2VT were higher in controls (0.98 (0.97–0.99) both with V-slope and with VEM) than those in COPD patients (0.72 (0.60–0.81) with V-slope and 0.64 (0.50–0.74) with VEM). Passing–Bablok analysis showed that human and computerized determination of V˙O2VT was interchangeable in controls but not in patients with COPD. Forced expiratory volume in one second and peak minute ventilation during exercise were the only variables independently associated with greater interobserver differences in V˙O2VT. Interobserver differences in HRVT ranged from 2 ± 1 (controls) to 10 ± 3 bpm (GOLD 4).
CONCLUSIONSIn patients with COPD, the reliability of human estimation of V˙O2VT is less than that in controls and not interchangeable with a computerized analysis. This should be taken into account when using VT for exercise prescription, as a tool to monitor responses to an intervention, as a surrogate measure of overall aerobic fitness, or as a prognostic marker in patients with COPD.