Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 8 von 559

Details

Autor(en) / Beteiligte
Titel
Coronary evaginations and peri-scaffold aneurysms following implantation of bioresorbable scaffolds: incidence, outcome, and optical coherence tomography analysis of possible mechanisms
Ist Teil von
  • European heart journal, 2016-07, Vol.37 (26), p.2040-2049
Ort / Verlag
England
Erscheinungsjahr
2016
Quelle
Oxford Journals 2020 Medicine
Beschreibungen/Notizen
  • Peri-stent coronary evaginations may disturb flow and have been proposed as possible risk factor for late stent thrombosis. We describe incidence, predictors, and possible mechanisms of coronary evaginations 12 months after implantation of bioresorbable vascular scaffolds (BVS). One hundred and two BVS implanted in 90 patients (age 63 ± 13 years, 71 males, 14 diabetics) were analysed with angiography and optical coherence tomography (OCT) 12 months after implantation. Evaginations were identified as any hollow in the luminal vessel contour between well-apposed struts and were classified as major when extending ≥3 mm with a depth ≥10% of the BVS diameter. Fifty-five (54%) of the BVS (50(56%) of the patients) had at least one evagination (6.1 ± 6.2 evaginations per BVS), with a mean volume of 1.9 ± 1.9 mm(3). Major evaginations were only found in one patient, and in-BVS aneurysms in three patients (4BVS). The presence of evaginations was strongly associated with that of malapposition (P = 0.003) and strut fractures (P = 0.01). No association could be shown between the presence and volume of the evaginations and any clinical variable or the presence of uncovered struts (P > 0.5). Peri-strut low-intensity areas (PSLIA) were present in 29 (53%) of the BVS with evaginations and 12 (26%) of those without (P = 0.0049); their presence was independently associated with the presence, the number (P < 0.003) and volume of the evaginations (P = 0.004) and with that of strut fracture. Optical coherence tomography-detected evaginations are relatively common after BVS implantation, but, as for modern drug-eluting metallic stents, major evaginations are very rare. Optical coherence tomography evidence of immature neointima and strut fractures were associated with more severe development of evaginations.
Sprache
Englisch
Identifikatoren
ISSN: 0195-668X
eISSN: 1522-9645
DOI: 10.1093/eurheartj/ehv581
Titel-ID: cdi_proquest_miscellaneous_1808672269

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX