Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 2 von 201
International journal of electrical power & energy systems, 2016-09, Vol.80, p.52-63
2016
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Automatic generation control of a multi-area system using ant lion optimizer algorithm based PID plus second order derivative controller
Ist Teil von
  • International journal of electrical power & energy systems, 2016-09, Vol.80, p.52-63
Ort / Verlag
Elsevier Ltd
Erscheinungsjahr
2016
Quelle
Elsevier ScienceDirect Journals
Beschreibungen/Notizen
  • •Maiden application of PID+DD controller to multi area power system.•ALO is used in AGC for the first time to optimize controller gains.•PID+DD controller provides better responses than I, PI and PID controllers.•Sensitivity analysis reveals robustness of PID+DD controller.•In random loading pattern condition also PID+DD controller performs well. This article presents the automatic generation control of an unequal three area thermal system. Single stage reheat turbines and generation rate constraints of 3%/min are considered in each control area. Controllers such as Integral (I), Proportional – Integral (PI), Proportional – Integral – Derivative (PID), and Proportional – Integral – Derivative Plus Second Order Derivative (PID+DD) are treated as secondary controllers separately. A nature inspired optimization technique called Ant Lion Optimizer (ALO) algorithm is used for simultaneous optimization of the controller gains. Comparison of dynamic responses of frequencies and tie line powers corresponding to ALO optimized I, PI, PID and PID+DD controller reveal the better performance of PID+DD controller in terms of lesser settling time, peak overshoots as well as reduced oscillations. Robustness of the optimum gains of best controller obtained at nominal conditions is evaluated using sensitivity analysis. Analysis exposed that the optimum PID+DD controller gains obtained at nominal are robust and not necessary to reset again for changes in loading, parameter like inertia constant (H), size and position of disturbance. Furthermore, the performance of PID+DD controller is found better as compared to PID controller against random loading pattern condition.
Sprache
Englisch
Identifikatoren
ISSN: 0142-0615
eISSN: 1879-3517
DOI: 10.1016/j.ijepes.2016.01.037
Titel-ID: cdi_proquest_miscellaneous_1808124755

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX