Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 16 von 156

Details

Autor(en) / Beteiligte
Titel
Does powdering of the dentition increase the accuracy of fusing 3D stereophotographs and digital dental casts
Ist Teil von
  • European journal of orthodontics, 2016-08, Vol.38 (4), p.440-445
Ort / Verlag
England
Erscheinungsjahr
2016
Link zum Volltext
Quelle
Oxford Journals 2020 Medicine
Beschreibungen/Notizen
  • The shiny vestibular surfaces of teeth make it difficult to match digital dental casts to 3D stereophotogrammetric images of patient teeth. This study tested whether reducing this shininess by coating the teeth with titanium-oxide powder might improve the accuracy of the matching procedure. Twenty patients participated in the study. For each patient, 3D stereophotogrammetric images were taken without and with a powder coating. Separately, digital dental casts were created. Next, the digital dental casts were fused with the 3D stereophotogrammetric images of either non-powdered or powdered dentition. Distance maps were created to evaluate the inter-surface distance between the digital dental cast and the 3D images. The matching accuracy was compared for dentition with and without powdering. Of all recorded distances between corresponding points, 95% was smaller than 0.84mm for the powdered dentition and smaller than 0.90mm for the non-powdered dentition. Although powdered dentition showed significantly better matching than non-powdered dentition, the difference was less than 0.1mm. Intra-observer statistics showed that five out of 24 repetitions gave significantly different results, but only for dentition that was not powdered. The patients did not have any major malocclusions. Severe malocclusions might cause greater difficulty in matching the dentition without powder. Only one type of powder was used, but it effectively reduced shininess. Powdering the dentition had a small, but significant, positive effect on matching. However, this effect was of minor clinical importance. Therefore, we do not recommend powdering the dentition for 3D stereophotogrammetric images used for matching procedures.
Sprache
Englisch
Identifikatoren
ISSN: 0141-5387
eISSN: 1460-2210
DOI: 10.1093/ejo/cjw001
Titel-ID: cdi_proquest_miscellaneous_1807901455

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX