Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 17 von 695

Details

Autor(en) / Beteiligte
Titel
Field studies of thermal comfort across multiple climate zones for the subcontinent: India Model for Adaptive Comfort (IMAC)
Ist Teil von
  • Building and environment, 2016-03, Vol.98, p.55-70
Ort / Verlag
Elsevier Ltd
Erscheinungsjahr
2016
Quelle
Access via ScienceDirect (Elsevier)
Beschreibungen/Notizen
  • India is witnessing unprecedented growth trends in building construction, particularly office spaces. Indian offices are designed to operate at 22.5 ± 1 °C all year round to meet the stringent “Class A” specifications outlined by international standards in the absence of an India-specific comfort standard. This paper proposes an India Model for Adaptive Comfort – IMAC – based on the field surveys administered in 16 buildings in three seasons and five cities, representative of five Indian climate zones. A total of 6330 responses were gathered from naturally ventilated, mixed mode and air-conditioned office buildings using instantaneous thermal comfort surveys. Occupants in naturally ventilated Indian offices were found to be more adaptive than the prevailing ASHRAE and EN models would suggest. According to the IMAC model, neutral temperature in naturally ventilated buildings varies from 19.6 to 28.5 °C for 30-day outdoor running mean air temperatures ranging from 12.5 to 31 °C. This is the first instance where a study proposes a single adaptive model for mixed mode buildings asserting its validity for both naturally ventilated and air-conditioned modes of operation in the building, with neutral temperature varying from 21.5 to 28.7 °C for 13–38.5 °C range of outdoor temperatures. For air-conditioned buildings, Fanger's static PMV model was found to consistently over-predict the sensation on the warmer side of the 7-point sensation scale. •A single adaptive model is proposed for NV and AC modes of operation.•Indian office occupants are more adaptive than predicted by ASHRAE-55 and EN15251 models.•International comfort standards are not appropriate for Indian office buildings.•Occupants in MM offices are more adaptive than those in AC and less adaptive than those in NV offices.•Fan and window operation, change in clothing are significant adaptive measures in NV offices.
Sprache
Englisch
Identifikatoren
ISSN: 0360-1323
eISSN: 1873-684X
DOI: 10.1016/j.buildenv.2015.12.019
Titel-ID: cdi_proquest_miscellaneous_1793242396

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX