Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 7 von 107

Details

Autor(en) / Beteiligte
Titel
Estimated Risk Level of Unified Stereotactic Body Radiation Therapy Dose Tolerance Limits for Spinal Cord
Ist Teil von
  • Seminars in radiation oncology, 2016-04, Vol.26 (2), p.165-171
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2016
Quelle
ScienceDirect
Beschreibungen/Notizen
  • A literature review of more than 200 stereotactic body radiation therapy spine articles from the past 20 years found only a single article that provided dose-volume data and outcomes for each spinal cord of a clinical dataset: the Gibbs 2007 article (Gibbs et al, 2007 ), which essentially contains the first 100 stereotactic body radiation therapy (SBRT) spine treatments from Stanford University Medical Center. The dataset is modeled and compared in detail to the rest of the literature review, which found 59 dose tolerance limits for the spinal cord in 1-5 fractions. We partitioned these limits into a unified format of high-risk and low-risk dose tolerance limits. To estimate the corresponding risk level of each limit we used the Gibbs 2007 clinical spinal cord dose-volume data for 102 spinal metastases in 74 patients treated by spinal radiosurgery. In all, 50 of the patients were previously irradiated to a median dose of 40 Gy in 2-3 Gy fractions and 3 patients developed treatment-related myelopathy. These dose-volume data were digitized into the dose-volume histogram (DVH) Evaluator software tool where parameters of the probit dose-response model were fitted using the maximum likelihood approach (Jackson et al, 1995 ). Based on this limited dataset, for de novo cases the unified low-risk dose tolerance limits yielded an estimated risk of spinal cord injury of ≤1% in 1-5 fractions, and the high-risk limits yielded an estimated risk of ≤3%. The QUANTEC Dmax limits of 13 Gy in a single fraction and 20 Gy in 3 fractions had less than 1% risk estimated from this dataset, so we consider these among the low-risk limits. In the previously irradiated cohort, the estimated risk levels for 10 and 14 Gy maximum cord dose limits in 5 fractions are 0.4% and 0.6%, respectively. Longer follow-up and more patients are required to improve the risk estimates and provide more complete validation.
Sprache
Englisch
Identifikatoren
ISSN: 1053-4296
eISSN: 1532-9461
DOI: 10.1016/j.semradonc.2015.11.010
Titel-ID: cdi_proquest_miscellaneous_1775380922

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX