Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 23 von 50

Details

Autor(en) / Beteiligte
Titel
Quantification Analysis of the Intraoperative Bacterial Contamination Rate and Level in Osteochondral Autografts
Ist Teil von
  • The American journal of sports medicine, 2016-03, Vol.44 (3), p.761-766
Ort / Verlag
Los Angeles, CA: SAGE Publications
Erscheinungsjahr
2016
Quelle
MEDLINE
Beschreibungen/Notizen
  • Background: Inadvertent contamination of osteochondral (OC) autografts during harvesting and preparation can lead to significant complications and can cause the operating team to weigh the infection risk after reimplantation against discarding the OC fragment. The most commonly reported contamination mechanism is the accidental dropping of an OC fragment; however, associated contamination levels remain unclear. The rate and level of contamination during standard harvesting and preparation are also unknown. Purpose: To quantitatively evaluate the rate and level of bacterial contamination of OC autografts during harvesting and preparation compared with those of accidently dropped autografts. Study Design: Controlled laboratory study. Methods: Under sterile conditions, 138 fresh OC specimens were harvested and retrieved from 23 primary total knee arthroplasties (TKAs). Six OC fragments were retrieved from each TKA: 3 were used as controls, and 3 were dropped onto the operating room floor. Each specimen was incubated to allow for aerobic and anaerobic growth, and the number of colony-forming units (CFUs) per gram was calculated. Results: Contamination rates (positive cultures) for the control and dropped groups were 29% (n = 20/69) and 42% (n = 29/69), respectively. The difference in the contamination rate between groups was not statistically significant (P = .109). The most common organisms identified were Staphylococcus aureus (40%) in the control group and Staphylococcus epidermidis (24.1%) and Bacillus species (20.7%) in the dropped group. The contamination level (CFUs/g) for both groups was low. The median (range) CFUs/g among the contaminated specimens in the dropped and control groups were 27 (1-120) and 3 (1-15), respectively (P < .0001). Conclusion: A relatively high rate of OC autograft contamination can be expected during harvesting and preparation (29%) or after accidentally dropping a specimen (42%). Although the types of organisms isolated differed between specimens contaminated during harvesting and preparation and dropped specimens, the quantification of the autograft contamination level revealed a very low CFUs/g in both cases. Clinical Relevance: The intraoperative autograft contamination level is very low. Hence, in cases of grafts with a known contamination incident, saving and reimplanting them after proper decontamination is recommended over discarding them or using an allograft.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX