Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Fabrication of bimetallic microfluidic surface-enhanced Raman scattering sensors on paper by screen printing
Ist Teil von
Analytica chimica acta, 2013-08, Vol.792, p.86-92
Ort / Verlag
Netherlands: Elsevier B.V
Erscheinungsjahr
2013
Quelle
MEDLINE
Beschreibungen/Notizen
•An Au–Ag bimetallic microfluidic, dumbbell-shaped SERS sensors were fabricated.•The sensor was fabricated on cellulose paper by screen printing.•The sensor could enable self-filtering of fluids to remove suspended particles within wastewater without pumping.•The detection zone of the sensor allows sensitive SERS detection.
Au–Ag bimetallic microfluidic, dumbbell-shaped, surface enhanced Raman scattering (SERS) sensors were fabricated on cellulose paper by screen printing. These printed sensors rely on a sample droplet injection zone, and a SERS detection zone at either end of the dumbbell motif, fabricated by printing silver nanoparticles (Ag NPs) and gold nanoparticles (Au NPs) successively with microscale precision. The microfluidic channel was patterned using an insulating ink to connect these two zones and form a hydrophobic circuit. Owing to capillary action of paper in the millimeter-sized channels, the sensor could enable self-filtering of fluids to remove suspended particles within wastewater without pumping. This sensor also allows sensitive SERS detection, due to advantageous combination of the strong surface enhancement of Ag NPs and excellent chemical stability of Au NPs. The SERS performance of the sensors was investigated by employing the probe rhodamine 6G, a limit of detection (LOD) of 1.1×10−13M and an enhancement factor of 8.6×106 could be achieved. Moreover, the dumbbell-shaped bimetallic sensors exhibited good stability with SERS performance being maintained over 14 weeks in air, and high reproducibility with less than 15% variation in spot-to-spot SERS intensity. Using these dumbbell-shaped bimetallic sensors, substituted aromatic pollutants in wastewater samples could be quantitatively analyzed, which demonstrated their excellent capability for rapid trace pollutant detection in wastewater samples in the field without pre-separation.