Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 11 von 48

Details

Autor(en) / Beteiligte
Titel
Comparison between balanced steady-state free precession and standard spoiled gradient echo magnetization transfer ratio imaging in multiple sclerosis: methodical and clinical considerations
Ist Teil von
  • NeuroImage (Orlando, Fla.), 2015-03, Vol.108, p.87-94
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2015
Quelle
MEDLINE
Beschreibungen/Notizen
  • Different pathological processes like demyelination and axonal loss can alter the magnetisation transfer ratio (MTR) in brain tissue. The standard method to measure this effect is to scan the respective tissue twice, one with and one without a specific saturation pulse. A major drawback of this technique based on spoiled gradient echo (GRE) sequences relates to its long acquisition time due to the saturation pulses. Recently, an alternative concept for MT imaging based on balanced steady state free precession (bSSFP) has been proposed. Modification of the duration of the radiofrequency pulses for imaging allows scanning MT sensitive and non-sensitive images. The steady-state character of bSSFP with high intrinsic signal-to-noise ratio (SNR) allows three-dimensional (3D) whole brain MTR at high spatial resolution within short and thus clinically feasible acquisition times. In the present study, both bSSFP-MT and 2D GRE-MT imaging were used in a cohort of 31 patients with multiple sclerosis (MS) to characterize different normal appearing (NA) and pathological brain structures. Under the constraint of identical SNR and scan time, a 3.4 times higher voxel size could be achieved with bSSFP. This increased resolution allowed a more accurate delineation of the different brain structures, especially of cortex, hippocampus and MS lesions. In a multiple linear regression model, we found an association between MTR of cortical lesions and a clinical measure of disability (r= −0.407, p=0.035) in the bSSFP dataset only. The different relaxation weighting of the base images (T2/T1 in bSSFP, proton density in GRE) had no effects besides a larger spreading of the MTR values of the different NA structures. This was demonstrated by the nearly perfect linearity between the NA matter MTR of both techniques as well as in the absolute MTR differences between NA matter and the respective lesions. •We examined 31 MS patients with two magnetization transfer ratio (MTR) techniques.•balanced steady state free precession (bSSFP) was compared with gradient echo (GRE).•Using bSSFP, we gained 3.4 higher spatial resolution compared to standard GRE.•We found nearly perfect linearity between the MTR values of both techniques.•bSSFP MTR maps demonstrate improved correlation to clinical outcomes.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX