A Biomechanical Comparison of 2 Hybrid Techniques for Elbow Ulnar Collateral Ligament Reconstruction
Ist Teil von
  • The Journal of hand surgery (American ed.), 2014-10, Vol.39 (10), p.2033-2040
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2014
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • Purpose To compare the valgus laxity and fixation strength of 2 hybrid techniques for elbow ulnar collateral ligament reconstructions. Methods Reflective markers were placed near the ligament attachments of the ulnar collateral ligament on the humerus and ulna of 12 fresh-frozen cadaveric upper extremities for tracking displacement with 4 motion analysis cameras. Valgus laxity testing was performed on the intact, disrupted ligament, and reconstructed elbows by applying a 3.0 Nm moment across the joint at 15° intervals throughout elbow motion from 0° to 120°. Two hybrid techniques for ulnar collateral ligament reconstruction were performed: a proximal docking method and a single-point distal fixation method. Failure testing was performed with the elbow at 90° by applying a cyclic valgus load 12 cm distal to the joint that we increased in 10-N intervals. Results Valgus laxity testing revealed no difference in ligament displacements between the 2 techniques over the entire range of elbow motion. Ligament displacement for the proximal docking hybrid technique was significantly higher than the intact at 0° and 15° of elbow flexion. Failure testing revealed no differences in ligament displacements or failure load between the 2 techniques. Conclusions Both the proximal docking and the single-point fixation hybrid reconstructions provided sufficient joint stability and strength compared to the intact elbows, with the exception of the proximal docking method at low flexion angles. The reconstructions were not significantly different with respect to valgus laxity or graft fixation displacement at failure. Clinical relevance The proximal docking and single-point fixation hybrids tested here are both viable surgical options with sufficient strength and valgus laxity mechanics, warranting clinical evaluation.
Sprache
Englisch
Identifikatoren
ISSN: 0363-5023
eISSN: 1531-6564
DOI: 10.1016/j.jhsa.2014.07.040
Titel-ID: cdi_proquest_miscellaneous_1566112664

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX