Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 8 von 1740

Details

Autor(en) / Beteiligte
Titel
Mechanical Circulatory Support in Advanced Heart Failure: Single-Center Experience
Ist Teil von
  • Transplantation proceedings, 2014-06, Vol.46 (5), p.1476-1480
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2014
Quelle
Access via ScienceDirect (Elsevier)
Beschreibungen/Notizen
  • Abstract Background Currently, ventricular assist device (VAD) or total artificial heart (TAH) mechanical support provides an effective treatment of unstable patients with advanced heart failure. We report our single-center experience with mechanical circulatory support therapy. Methods From March 2002 to December 2012, 107 adult patients (mean age, 56.8 ± 9.9 y; range, 31–76 y) were primarly supported on temporary or long-term VAD or TAH support as treatment for refractory heart failure at our institution. Temporary extracorporeal radial VAD support (group A) was established in 49 patients (45.7%), and long-term paracorporeal and intracorporeal VAD or TAH (group B) in 58 patients (54.2%). Left ventricular (LVAD) support was established in 55 patients (51.4%; n  = 33, Heartmate II; n  = 6, Heartmate I XVE; n  = 4, Heartware HVAD; and n  = 12, Centrimag) and biventricular (BVAD/TAH) support (group B) in 28 patients (26.1%; n  = 10, Thoratec paracorporeal; n  = 2, Heartware HVAD, n  = 1, Thoratec implantable; n  = 1, Syncardia TAH; and n  = 14, Centrimag). The temporary Centrimag was the only device adopted as isolated right ventricular (RVAD) support, and it was inserted in 24 patients (22.4%). Results In group A, overall mean support time was 10.2 ± 6.6 days (range, 3–43 d). In group B, LVAD mean support time was 357 ± 352.3 days (range, 1–902 d) and BVAD/TAH support time was 98 ± 82.6 days (range, 8–832 d). In group A, the overall success rate was 55.1% (27 patients). In group B, LVAD overall success rate was 74.4% (32 patients) and BVAD/TAH success rate was 50% (7 patients). Overall heart transplantation rate for both groups was 27.1% ( n  = 2, group A; n  = 27, group B). Overall 1-year and 5-year survivals after heart transplantation were 72.4% ( n  = 21) and 58.6% ( n  = 17), respectively. Conclusions Mechanical circulatory support is an effective strategy even in cases of end-stage heart failure according to our experience. Further improvement of VAD and TAH technologies may support their adoption as an encouraging alternative to heart transplantation in the near future.
Sprache
Englisch
Identifikatoren
ISSN: 0041-1345
eISSN: 1873-2623
DOI: 10.1016/j.transproceed.2014.01.016
Titel-ID: cdi_proquest_miscellaneous_1537179829

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX