  • Abstract Background We previously showed that ringed polytetrafluoroethylene (PTFE) grafts combined with small allograft patches showed high patency rates similar to those of iliac vein grafts and therefore that they can be used for middle hepatic vein (MHV) reconstruction. Although such use of PTFE graft showed high patency rates, its long-term safety regarding infection and other types of complications were not presented. In this study, we investigated the actual risk of complications directly associated with PTFE graft interposition for MHV reconstruction. Methods During the study period of 30 months, we performed 215 cases of adult living-donor liver transplantation with modified right lobe graft and PTFE grafts. We classified the potential complications directly associated with PTFE graft interposition as infectious and surgical complications. The medical records of study patients were retrospectively reviewed. Results MHV graft patency rate was 76.3% at 6 months and 36.7% at 12 months. Their 1-year graft and patient survival rates were 92.6% and 93.5%, respectively. The 1-year actual incidences of infectious complication and surgical complication were near zero and 1 case (0.5%), respectively. In 1 recipient, the PTFE graft penetrated into the stomach wall 6 months after transplantation, but the patient did not complain of any specific symptoms. The PTFE graft was removed with the use of laparotomy, and the patient recovered uneventfully. Conclusions Although the incidence of PTFE graft–associated complication rate is very low, we suggest that it is necessary to closely monitor the PTFE graft, because unexpected complications can happen during long-term follow-up.
Sprache
Englisch
Identifikatoren
ISSN: 0041-1345
eISSN: 1873-2623
DOI: 10.1016/j.transproceed.2013.10.054
Titel-ID: cdi_proquest_miscellaneous_1519847753

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX