Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 21 von 1091

Details

Autor(en) / Beteiligte
Titel
Accuracy of Fluorodeoxyglucose-Positron Emission Tomography Within the Clinical Practice of the American College of Surgeons Oncology Group Z4031 Trial to Diagnose Clinical Stage I Non-Small Cell Lung Cancer
Ist Teil von
  • The Annals of thoracic surgery, 2014-04, Vol.97 (4), p.1142-1148
Ort / Verlag
Netherlands: Elsevier Inc
Erscheinungsjahr
2014
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • Background Fluorodeoxyglucose-positron emission tomography (FDG-PET) is recommended for diagnosis and staging of non-small cell lung cancer (NSCLC). Meta-analyses of FDG-PET diagnostic accuracy demonstrated sensitivity of 96% and specificity of 78% but were performed in select centers, introducing potential bias. This study evaluates the accuracy of FDG-PET to diagnose NSCLC and examines differences across enrolling sites in the national American College of Surgeons Oncology Group (ACOSOG) Z4031 trial. Methods Between 2004 and 2006, 959 eligible patients with clinical stage I (cT1-2 N0 M0) known or suspected NSCLC were enrolled in the Z4031 trial, and with a baseline FDG-PET available for 682. Final diagnosis was determined by pathologic examination. FDG-PET avidity was categorized into avid or not avid by radiologist description or reported maximum standard uptake value. FDG-PET diagnostic accuracy was calculated for the entire cohort. Accuracy differences based on preoperative size and by enrolling site were examined. Results Preoperative FDG-PET results were available for 682 participants enrolled at 51 sites in 39 cities. Lung cancer prevalence was 83%. FDG-PET sensitivity was 82% (95% confidence interval, 79 to 85) and specificity was 31% (95% confidence interval, 23% to 40%). Positive and negative predictive values were 85% and 26%, respectively. Accuracy improved with lesion size. Of 80 false-positive scans, 69% were granulomas. False-negative scans occurred in 101 patients, with adenocarcinoma being the most frequent (64%), and 11 were 10 mm or less. The sensitivity varied from 68% to 91% ( p  = 0.03), and the specificity ranged from 15% to 44% ( p  = 0.72) across cities with more than 25 participants. Conclusions In a national surgical population with clinical stage I NSCLC, FDG-PET to diagnose lung cancer performed poorly compared with published studies.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX