Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 1 von 58

Details

Autor(en) / Beteiligte
Titel
Evaluation of the biodegradable peripheral Igaki-Tamai stent in the treatment of de novo lesions in the superficial femoral artery: the GAIA study
Ist Teil von
  • JACC. Cardiovascular interventions, 2014-03, Vol.7 (3), p.305-312
Ort / Verlag
United States
Erscheinungsjahr
2014
Quelle
Elsevier ScienceDirect Journals
Beschreibungen/Notizen
  • This study sought to evaluate the safety and performance of the Igaki-Tamai (Igaki Medical Planning Company, Kyoto, Japan) biodegradable stent in patients with occlusive superficial femoral artery (SFA) disease. Poly-L-lactic acid (PLLA) biodegradable stents have been shown to be effective in the coronaries, but no data are available regarding their efficacy in the femoral artery. A prospective, multicenter, nonrandomized study enrolled 30 patients with symptomatic de novo SFA disease undergoing implantation of Igaki-Tamai bioresorbable stents. Clinical examinations and duplex ultrasound were prospectively performed after 1, 6, 9, and 12 months. The main study endpoints were technical success, restenosis rate, rate of target lesion revascularization (TLR), changes in ankle-brachial index (ABI), and quality of life by evaluating the walking impairment questionnaire (WIQ). Safety was assessed by monitoring the occurrence of major adverse clinical events and serious adverse events. The mean age of the patients was 67.7 years, and 77% were male. The mean lesion length was 5.9 cm. Mean diameter stenosis was reduced from 89.9% to 6.2%, after stent implantation. Technical success was 96.7%. Binary restenosis rate for the 6 and 12 months follow-up was 39.3% and 67.9%, respectively. The TLR rate was 25.0% after 6 months and 57.1% after 12 months. All TLR were successful; the secondary patency rate after 1 year was 89.3%. Between baseline and 12 months, ABI increased in 53.6% of patients. Functional endpoints (WIQ), even if affected by a relatively high reintervention rate, showed improvement in most of the patients. The GAIA (Evaluation of the Biodegradable Peripheral Igaki-Tamai Stent in the Treatment of De Novo Lesions in the Superficial Femoral Artery) study shows that when using biodegradable PLLA stents (Igaki-Tamai), the immediate angiographic results are comparable to the results of metal stents, achieving a high secondary patency rate after 1 year. Modifications of stent characteristics and technical modifications are needed with the goal to reduce the restenosis rate during the reabsorption period.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX