Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 2 von 15827
Obstetrics and gynecology (New York. 1953), 2013-12, Vol.122 (6), p.1160-1167
2013

Details

Autor(en) / Beteiligte
Titel
Accuracy of Ultrasonography at 11–14 Weeks of Gestation for Detection of Fetal Structural Anomalies: A Systematic Review
Ist Teil von
  • Obstetrics and gynecology (New York. 1953), 2013-12, Vol.122 (6), p.1160-1167
Ort / Verlag
United States: by The American College of Obstetricians and Gynecologists
Erscheinungsjahr
2013
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • OBJECTIVE:To review the literature concerning the efficacy of early ultrasonography (at 11–14 weeks of gestation) to identify fetal malformations. DATA SOURCES:A search in PubMed, MEDLINE, Embase, Cochrane Library, and ClinicalTrials.gov was performed (January 2000 to December 2012). Keywords werefetal anatomy, fetal echocardiography, nuchal translucency, fetal structural anomalies, fetal malformations, prenatal diagnosis, prenatal screening, and first-trimester ultrasonography. METHODS OF STUDY SELECTION:Inclusion criteria werefetal anatomy examination at early ultrasonography and diagnosis of fetal malformations confirmed by postnatal or postmortem examination. Data abstracted weresample size, location of structural defect, ultrasound modality, presence of multiple defects, and study population. Pooled detection rate was calculated for each malformation and compared with χ. Differences were considered statistically significant if P<.05. TABULATION, INTEGRATION, AND RESULTS:From 1,203 articles, 19 were included. Overall, we pooled 78,002 fetuses undergoing ultrasonography at 11–14 weeks, of which 996 were malformed, leading to prevalence of malformation of 12 per 1,000. The overall detection rate was 472 of 957 (51%). The highest detection rate was achieved for neck anomalies (92%), whereas limbs (34%), face (34%), and genitourinary anomalies (34%) were associated with the lowest detection rate. At 14 weeks of gestation or less, fetal echocardiography detected 53% of congenital heart disease compared with 43% by complete scan (P=.040). The use of Doppler did not improve the detection rate for congenital heart defects (52% compared with 44%, respectively; P=.11). Multiple defects were identified more frequently than isolated malformations (60% compared with 44%; P=.005). The detection rate was higher combining transabdominal and transvaginal techniques (62%) than either abdominal (51%) or transvaginal (34%; P<.001). Detection rate was higher in women at high risk (65%) than unselected population (50% P=.001). CONCLUSION:Because of the natural history of fetal defects and the late development of some organ systems, a number of fetal malformations remain undetected by early ultrasonography.
Sprache
Englisch
Identifikatoren
ISSN: 0029-7844
eISSN: 1873-233X
DOI: 10.1097/AOG.0000000000000015
Titel-ID: cdi_proquest_miscellaneous_1461337346

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX