Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 22 von 8873
Computer methods in applied mechanics and engineering, 2013-04, Vol.257, p.103-116
2013

Details

Autor(en) / Beteiligte
Titel
Fluid–structure interaction, immersed boundary-finite element method simulations of bio-prosthetic heart valves
Ist Teil von
  • Computer methods in applied mechanics and engineering, 2013-04, Vol.257, p.103-116
Ort / Verlag
Elsevier B.V
Erscheinungsjahr
2013
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • ► Fully-resolved 3D fluid–structure interaction simulations of bio-prosthetic heart valves. ► Anisotropic non-linear experimentally obtained material model for heart valve tissue. ► Break down of flow symmetry questions the symmetry assumption of previous work. ► Simulations show significant differences between mechanical and bio-prosthetic flow. A three-dimensional fluid–structure interaction (FSI) framework for rigid bodies has been extended to deformable soft tissue by coupling a sharp-interface immersed boundary incompressible Navier–Stokes solver for fluids with a non-linear large deformation finite element method for soft tissue. A Fung-type constitutive law is used for the soft tissue of heart valves that can capture the experimentally observed non-linear anisotropic stress–strain behavior of the heart valve tissue. The FSI solver adopts a strongly-coupled partitioned approach that is stabilized with under-relaxation and the Aitken acceleration technique. The finite element solver is verified against the benchmark experimental and numerical data for heart valve tissue while the immersed boundary solver was validated against flow measurements of a mechanical heart valve in the previous work. The capabilities of the solver are demonstrated by simulating the first fully three-dimensional fluid–structure interaction of tissue valves implanted in the aortic position during systole under physiologic flow conditions. It is observed that the flow’s threefold symmetry breaks during the early systole, questioning the threefold symmetry assumption of previous simulations. The flow created by the tissue valve is compared against the mechanical heart valve under the same conditions. The flowfields, created by the tissue and mechanical valves, show drastic differences at different instances during a heartbeat cycle. Mainly, the breakdown of vortices into small-scale vortical structures right before the peak systole in mechanical heart valves is not observed in the bio-prosthetic heart valves.
Sprache
Englisch
Identifikatoren
ISSN: 0045-7825
eISSN: 1879-2138
DOI: 10.1016/j.cma.2013.01.010
Titel-ID: cdi_proquest_miscellaneous_1448717004

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX