Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 21 von 26

Details

Autor(en) / Beteiligte
Titel
A Randomized Study of Cardiac Resynchronization Therapy Defibrillator Versus Dual-Chamber Implantable Cardioverter-Defibrillator in Ischemic Cardiomyopathy With Narrow QRS: The NARROW-CRT Study
Ist Teil von
  • Circulation. Arrhythmia and electrophysiology, 2013-06, Vol.6 (3), p.538-545
Ort / Verlag
United States: American Heart Association, Inc
Erscheinungsjahr
2013
Quelle
MEDLINE
Beschreibungen/Notizen
  • BACKGROUND—Current recommendations require a QRS duration of ≥120 ms as a condition for prescribing cardiac resynchronization therapy (CRT). This study was designed to test the hypothesis that patients with heart failure (HF) of ischemic origin, current indications for defibrillator implantation, and QRS <120 ms may benefit from CRT in the presence of marked mechanical dyssynchrony. METHODS AND RESULTS—Patients with intraventricular dyssynchrony on echocardiography were randomly assigned to CRT or dual-chamber defibrillator implantation (CRT defibrillator and dual-chamber implantable cardioverter-defibrillator arm, respectively). The primary end point was the HF clinical composite response, which scores patients as improved, unchanged, or worsened. The secondary end point was the cumulative survival from HF hospitalization and HF death. An additional secondary end point was the composite of HF hospitalization, HF death, and spontaneous ventricular fibrillation. Twenty-three of 56 patients with CRT defibrillator showed an improvement in their clinical composite response at 1 year, compared with 9 of 55 patients with dual-chamber implantable cardioverter-defibrillator (41% versus 16%; P=0.004). After a median follow-up of 16 months, the CRT defibrillator arm showed a nonsignificant higher survival from HF hospitalization and HF death (P=0.077), and a significantly higher survival from the combined end point of HF hospitalization, HF death, and spontaneous ventricular fibrillation (P=0.028). CONCLUSIONS—In this comparison of CRT defibrillator and dual-chamber implantable cardioverter-defibrillator, CRT improved clinical status in some patients with ischemic cardiomyopathy, mild-to-moderate symptoms, narrow QRS duration, and mechanical dyssynchrony on echocardiography. CLINICAL TRIAL REGISTRATION—URLhttp://clinicaltrials.gov. Unique identifierNCT01577446.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX