Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 9 von 111

Details

Autor(en) / Beteiligte
Titel
Balloon Valvuloplasty Through the Right Ventricle: Another Treatment of Pulmonary Atresia With Intact Ventricular Septum
Ist Teil von
  • The Annals of thoracic surgery, 2013-05, Vol.95 (5), p.1670-1674
Ort / Verlag
Netherlands: Elsevier Inc
Erscheinungsjahr
2013
Quelle
MEDLINE
Beschreibungen/Notizen
  • Background This was a study to evaluate the safety and feasibility of balloon valvuloplasty of the pulmonary valve through the right ventricle (RV) for the treatment of pulmonary atresia with intact ventricular septum (PA-IVS). Methods Ten neonates with PA-IVS, who underwent balloon valvuloplasty of the pulmonary valve through the RV at our institution from January 2008 to May 2010, were enrolled in this study. The oxygen saturation range was 60% to 83% (median 76%). The Z-value range of the tricuspid valve annulus was −2 to 2 (median 0.15), the diameter range of the pulmonary valve annulus was 4.6 to 8.6 mm (median 7.3), and the RV systolic pressure range was 88 to 124 mm Hg (median 106.5). A guidewire was used to perforate the pulmonary valve through the RV, followed by balloon dilation of the valve. The procedure was guided by transesophageal echocardiography. Results The procedure was carried out successfully in all patients. The procedure time ranged from 64 to 110 minutes (median 82.5). Mechanical ventilation time ranged from 8 to 36 hours (median 11), and hospital stay ranged from 7 to 13 days (median 9). After the procedure, the median oxygen saturation increased to 89.5%, the median RV systolic pressure decreased to 45 mm Hg, and the gradient across the pulmonary valve ranged from 20 to 45 mm Hg (median 27.5). Minor complications included transient supraventricular tachycardia (n = 1), blood loss requiring transfusion (n = 2), moderate pulmonary regurgitation (n = 1), and mild pulmonary regurgitation (n = 3). There were no cases of cardiac perforation, main pulmonary artery aneurysm, or low output syndrome. Follow-up of patients ranged from 8 to 15 months (median 12.3). All patients remained clinically well. Conclusions Balloon valvuloplasty of the pulmonary valve through the RV is a safe and feasible alternative to surgical valvotomy or percutaneous balloon dilation. Early results are encouraging.
Sprache
Englisch
Identifikatoren
ISSN: 0003-4975
eISSN: 1552-6259
DOI: 10.1016/j.athoracsur.2013.02.003
Titel-ID: cdi_proquest_miscellaneous_1345510643

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX