Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 2 von 32

Details

Autor(en) / Beteiligte
Titel
An effective retinal blood vessel segmentation method using multi-scale line detection
Ist Teil von
  • Pattern recognition, 2013-03, Vol.46 (3), p.703-715
Ort / Verlag
Kidlington: Elsevier Ltd
Erscheinungsjahr
2013
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Changes in retinal blood vessel features are precursors of serious diseases such as cardiovascular disease and stroke. Therefore, analysis of retinal vascular features can assist in detecting these changes and allow the patient to take action while the disease is still in its early stages. Automation of this process would help to reduce the cost associated with trained graders and remove the issue of inconsistency introduced by manual grading. Among different retinal analysis tasks, retinal blood vessel extraction plays an extremely important role as it is the first essential step before any measurement can be made. In this paper, we present an effective method for automatically extracting blood vessels from colour retinal images. The proposed method is based on the fact that by changing the length of a basic line detector, line detectors at varying scales are achieved. To maintain the strength and eliminate the drawbacks of each individual line detector, the line responses at varying scales are linearly combined to produce the final segmentation for each retinal image. The performance of the proposed method was evaluated both quantitatively and qualitatively on three publicly available DRIVE, STARE, and REVIEW datasets. On DRIVE and STARE datasets, the proposed method achieves high local accuracy (a measure to assess the accuracy at regions around the vessels) while retaining comparable accuracy compared to other existing methods. Visual inspection on the segmentation results shows that the proposed method produces accurate segmentation on central reflex vessels while keeping close vessels well separated. On REVIEW dataset, the vessel width measurements obtained using the segmentations produced by the proposed method are highly accurate and close to the measurements provided by the experts. This has demonstrated the high segmentation accuracy of the proposed method and its applicability for automatic vascular calibre measurement. Other advantages of the proposed method include its efficiency with fast segmentation time, its simplicity and scalability to deal with high resolution retinal images. ► We propose a vessel segmentation method based on the line detectors at varying scales. ► The proposed method is effective to deal with central reflex and close vessels. ► Our method achieves high local accuracy and good accuracy compared to other methods. ► The local accuracy is helpful to measure the accuracy at regions around the vessels. ► Vessel width measurements achieved by our method are highly correlated to manual ones.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX