Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 1 von 746

Details

Autor(en) / Beteiligte
Titel
Lung function is abnormal in 3-month-old infants with cystic fibrosis diagnosed by newborn screening
Ist Teil von
  • Thorax, 2012-10, Vol.67 (10), p.874-881
Ort / Verlag
London: BMJ Publishing Group Ltd and British Thoracic Society
Erscheinungsjahr
2012
Link zum Volltext
Quelle
BMJ Journals Archiv - DFG Nationallizenzen
Beschreibungen/Notizen
  • Background Long-term benefits of newborn screening (NBS) for cystic fibrosis (CF) have been established with respect to nutritional status, but effects on pulmonary health remain unclear. Hypothesis With early diagnosis and commencement of standardised treatment, lung function at ∼3 months of age is normal in NBS infants with CF. Methods Lung clearance index (LCI) and functional residual capacity (FRC) using multiple breath washout (MBW), plethysmographic (pleth) FRC and forced expirations from raised lung volumes were measured in 71 infants with CF (participants in the London CF Collaboration) and 54 contemporaneous healthy controls age ∼3 months. Results Compared with controls, and after adjustment for body size and age, LCI, FRCMBW and FRCpleth were significantly higher in infants with CF (mean difference (95% CI): 0.5 (0.1 to 0.9), p=0.02; 0.4 (0.1 to 0.7), p=0.02 and 0.9 (0.4 to 1.3), p<0.001, z-scores, respectively), while forced expiratory volume (FEV0.5) and flows (FEF25–75) were significantly lower (−0.9 (−1.3 to −0.6), p<0.001 and −0.7 (−1.1 to −0.2), p=0.004, z-scores, respectively). 21% (15/70) of infants with CF had an elevated LCI (>1.96 z-scores) and 25% (17/68) an abnormally low FEV0.5 (below −1.96 z-scores). While only eight infants with CF had abnormalities of LCI and FEV0.5, using both techniques identified abnormalities in 35% (24/68). Hyperinflation (FRCpleth >1.96 z-scores) was identified in 18% (10/56) of infants with CF and was significantly correlated with diminished FEF25–75 (r=−0.43, p<0.001) but not with LCI or FEV0.5. Conclusion Despite early diagnosis of CF by NBS and protocol-driven treatment in specialist centres, abnormal lung function, with increased ventilation inhomogeneity and hyperinflation and diminished airway function, is evident in many infants with CF diagnosed through NBS by 3 months of age.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX