Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 19 von 813

Details

Autor(en) / Beteiligte
Titel
Measures of performance for sentinel lymph node biopsy in oro-oropharyngeal squamous cell carcinoma: a systematic review and meta-analysis
Ist Teil von
  • Clinical and translational imaging : reviews in nuclear medicine and molecular imaging, 2023-12, Vol.11 (6), p.599-614
Ort / Verlag
Cham: Springer International Publishing
Erscheinungsjahr
2023
Link zum Volltext
Quelle
SpringerLink (Online service)
Beschreibungen/Notizen
  • Purpose The aim of this meta-analysis was to compare the reported sentinel lymph node detection rate (SDR), false-negative rate (FNR), and negative predictive value (NPV) as measures of performance of sentinel lymph node biopsy (SNB) techniques based on the use of radio-colloids, in clinically neck-negative T1/2 oro-oropharyngeal squamous cell carcinoma. Methods Studies were stratified according to the SNB technique: (1) 99m Tc-nanocolloid planar lymphoscintigraphy with the use of intra-operative hand-held gamma-probe (L-G); (2) L-G with the additional contribution of pre-operative SPECT/CT (L-SPECT/CT-G); (3) L-G with the additional contribution of intra-operative blue dye or indocyanine green optical tracers (L-G-O); (4) L-SPECT/CT-G with the additional contribution of optical tracers (L-SPECT/CT-G-O). The SDRs were summarized accordingly. To summarize the FNRs and NPVs: (i) the index test (SNB) was based on histological evaluation of resected sentinel lymph nodes (SLN) performed on immunohistochemistry and step serial sectioning; (ii) the reference standards were the elective neck dissection or follow-up for tumor-free SNB. Results From a total of 3693 patients, the overall SDRs for the L-G, L-SPECT/CT-G, L-G-O, and L-SPECT/CT-G-O techniques were 98.2% (95% CI 97–99.1), 98.9% (95% CI 97.5–99.7), 97.4% (95% CI 95.3–98.9), and 98% (95% CI 95.8–99.2). From a total of 1634 patients, the overall FNRs for the L-G, L-SPECT/CT-G and L-G-O techniques were 8.5% (95% CI 3.4–15.5), 6.2% (95% CI 0.9–15.7), and 9.1% (95% CI 4.3–15.4); moreover, the overall NPVs were 93% (95% CI 90.5–94.9), 91.2% (95% CI 88.3–93.8), and 93.9% (95% CI 90.9–96.3), respectively. Promising initial findings emerged from L-SPECT/CT-G-O. Conclusions The superiority of SPECT/CT over planar methods has been reported for providing identification of SLNs by aberrant lymphatic drainage. The additional contribution of optical tracers (mainly represented by blue dye) to the radiocolloid-based techniques did not improve significantly the measures of performance.
Sprache
Englisch
Identifikatoren
ISSN: 2281-7565, 2281-5872
eISSN: 2281-7565
DOI: 10.1007/s40336-023-00552-w
Titel-ID: cdi_proquest_journals_2894436447

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX