Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 5 von 14943
The Astrophysical journal. Supplement series, 2023-03, Vol.265 (1), p.10
2023
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Simultaneous Time-monitoring Observations of H2O and SiO Masers toward the Supergiant VX Sagittarii
Ist Teil von
  • The Astrophysical journal. Supplement series, 2023-03, Vol.265 (1), p.10
Ort / Verlag
Saskatoon: The American Astronomical Society
Erscheinungsjahr
2023
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • We performed simultaneous monitoring observations of the 22.2 GHz H2O and 43.1/42.8/86.2/129.3 GHz SiO masers toward the red supergiant VX Sagittarii using the Korean VLBI Network single-dish telescopes. The observations were conducted about every 2 months from 2013 May to 2019 January (30 epochs in total). They included four optical maxima in the active phase of the optical pulsation cycles. The line profile of a H2O maser always comprised various velocity components with a wider velocity range and varied from highly redshifted to blueshifted velocities with respect to the stellar velocity, in contrast to those of the SiO masers. We examined the relation between peak intensities and velocities of 11 detailed components in the line profile of the H2O maser and the pulsation phases. The peak intensity of each component generally exhibited a better correlation with the pulsation phases than that of total intensity. The peak velocities of several components gradually decreased or increased with respect to the stellar velocity, implying an accelerating motion and the development of asymmetries in the H2O maser region. The characteristics of four transition SiO maser properties were compared according to the stellar pulsation phases. The intensity and velocity variation trend of the 43.1 GHz SiO maser was similar to that of the 42.8 GHz SiO maser. However, the variation trend of the 43.1 and 42.8 GHz SiO masers was different from that of the 86.2 and 129.3 GHz SiO masers. This difference stems from the different location of each maser reflecting a different excitation condition.
Sprache
Englisch
Identifikatoren
ISSN: 0067-0049
eISSN: 1538-4365
DOI: 10.3847/1538-4365/acac8c
Titel-ID: cdi_proquest_journals_2778657885

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX