Am Donnerstag, den 15.8. kann es zwischen 16 und 18 Uhr aufgrund von Wartungsarbeiten des ZIM zu Einschränkungen bei der Katalognutzung kommen.
Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 14 von 246

Details

Autor(en) / Beteiligte
Titel
Expanding the calibration range of compound‐specific chlorine isotope analysis by the preparation of a 37Cl‐enriched tetrachloroethylene
Ist Teil von
  • Rapid communications in mass spectrometry, 2022-11, Vol.36 (21), p.n/a
Ort / Verlag
Bognor Regis: Wiley Subscription Services, Inc
Erscheinungsjahr
2022
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Rationale The recent development of reliable GC/qMS methods for δ37Cl compound‐specific stable isotope analysis (CSIA) paves the way for dual carbon–chlorine isotope analysis of chlorinated ethenes and thus allows deeper insights into underlying transformation processes/mechanisms. A two‐point calibration is indispensable for the precise and correct conversion of raw data to the international δ37ClSMOC scale. The currently available calibration standards for tetrachloroethylene (PCE) span only a very narrow range from −2.52‰ (EIL2) to +0.29‰ (EIL1), which is considerably smaller than observed δ37Cl isotope enrichment in (bio‐)transformation studies (up to 12‰). Methods We describe the preparation and evaluation of a new 37Cl‐enriched PCE standard to avoid bias in δ37Cl CSIA arising from extrapolation beyond the calibration range. The preparation comprised: (i) partial PCE reduction by zero‐valent zinc in a system of PCE, ethanol (initial volume ratio 3/5) and trace amounts of water followed by (ii) liquid–liquid extraction and (iii) a subsequent fractional distillation to purify the 37Cl‐enriched PCE. Results The obtained PCE (PCEenriched) showed a purity of 98.8% (mole fraction) and a δ37ClSMOC value of +10.8 ± 0.5‰. The evaluation of an experimental dataset with and without extrapolation showed no significant variation. Conclusions The new PCE standard (PCEenriched) expands the calibration range to 13.3‰ (previously 2.8‰) and thus prevents potential bias introduced by extrapolation beyond the calibration range.
Sprache
Englisch
Identifikatoren
ISSN: 0951-4198
eISSN: 1097-0231
DOI: 10.1002/rcm.9378
Titel-ID: cdi_proquest_journals_2720236177

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX